My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ALPINE
>
1624
>
2900 - Site Mitigation Program
>
PR0009012
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2018 10:03:55 PM
Creation date
11/1/2018 11:57:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0009012
PE
2960
FACILITY_ID
FA0004532
FACILITY_NAME
FRMR KEARNEY-KPF FACILITY
STREET_NUMBER
1624
Direction
E
STREET_NAME
ALPINE
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
APN
11708006-09
CURRENT_STATUS
01
SITE_LOCATION
1624 E ALPINE AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
555
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Memo to Gregory Vaughn -3- 6 March 1989 <br /> Page 26 The cluster site of a shallow, intermediate and deep monitoring <br /> wells proposed in the northeast corner of the site must be moved as it <br /> is within 100 feet of a leachfield and may violate San Joaquin County <br /> well siting regulations. This cluster site should be moved to the <br /> east or southeast of the main factory building which would be greater <br /> than 100 feet from the leachfields and will provide ground water flow <br /> control to the east. <br /> The shallow and deep monitoring wells (KI-2 and KD-2) cluster site <br /> proposed off-site to the southeast should be moved on-site to the <br /> northwest and should be included in a cluster with TP-2A. Moving <br /> this cluster on-site would eliminate the need for shallow well <br /> monitoring well KS-2. This cluster site would provide flow control to <br /> the southeast and is an on-site location to detect any potential <br /> contamination from adjacent off-site sources. <br /> The shallow monitoring well location (KS-4) proposed south of the main <br /> factory building should be eliminated, especially if a cluster site is <br /> placed to the east or southeast of the main factory building. A <br /> shallow monitoring well is needed in the immediate area of Pond l as <br /> this is currently inadequately monitored. If elevated concentrations <br /> of heavy metals are detected in the ground water from this well , <br /> additional monitoring wells will be required to determine the <br /> horizontal and vertical extent of ground water contamination. The <br /> shallow monitoring well location (KS-3) proposed in the northwesterly <br /> portion of the site is a good location for ground water flow control , <br /> but may be moved to the immediate area of Pond 2N if the 40 CFR <br /> prescriptive standard for three downgradient monitoring wells is <br /> required. <br /> Page 27 The intermediate monitoring well location (KI-4) proposed to the east <br /> of Pond 2N should be moved to the west and should be included in a <br /> cluster site with SMW-5 if possible, as this is the area of the <br /> highest concentrations of VOCs detected in ground water. An <br /> intermediate well should be added to the cluster site of SMW-3 and <br /> UMW-1 and should be located on the northwest side of DMW-1, to enable <br /> triangulation for this water-bearing zone. <br /> Page 28 A deep monitoring well should be included as part of a cluster site in <br /> the area southeast of Pond 2N as this is the area of the highest VOCs <br /> detected in the ground water. Based on electric logs from DMW-1 and <br /> CWS-77, the thickness of this coarse-grained zone is approximately 40 <br /> feet. The Hargis pian states that screen lengths will depend on the <br /> thickness of this coarse-grained interval . The screened interval for <br /> deep monitoring well should not be across potential separate water- <br /> bearing zones, but should be representative of a single water-bearing <br /> zone. <br /> Page 29 The duration of the aquifer testinq, the number of observation wells <br /> per test or the proposed methods of analyses was not included in this <br /> section. <br />