My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
500
>
2200 - Hazardous Waste Program
>
PR0220082
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/20/2021 2:12:46 PM
Creation date
11/1/2018 12:04:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0220082
PE
2220
FACILITY_ID
FA0000214
FACILITY_NAME
PILKINGTON NORTH AMERICA INC PLANT 10
STREET_NUMBER
500
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330-9739
CURRENT_STATUS
01
SITE_LOCATION
500 E LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\L\LOUISE\500\PR0220082\COMPLIANCE INFO 1989 - 1992.PDF
QuestysFileName
COMPLIANCE INFO 1989 - 1992
QuestysRecordDate
9/22/2017 9:10:01 PM
QuestysRecordID
3256138
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
954
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Inspection Report `, Pilkington <br /> 3. Minor Violation: On or about November 20, 2003 Pilkington was subject to the requirements <br /> of the Hazardous Waste Source Reduction and Management Review Act (also known as <br /> Senate Bill 14) and failed to prepare and retain current source reduction plan and make <br /> them available to the inspector. The Health & Safety Code, Division 20, Chapter 6.5, Article <br /> 11.9, section 25244.19 requires that generators that exceed annual thresholds of hazardous <br /> waste generation, in a reporting year (i.e.,2002), conduct a source reduction evaluation <br /> review and plan, a hazardous waste management performance report, and prepare and <br /> submit to DTSC a summary progress report, by September 1, 2003. Cal. Code of Regs., tit. <br /> 22, § 67100.5 states that generators subject to Senate Bill 14 requirements must have a <br /> Source Reduction Plan and Hazardous Waste Management Report available onsite for <br /> review. <br /> Required Action: Pilkington shall submit a plan and timeline to develop a Source Reduction <br /> Plan to Mr. Stephen Binning of DTSC within 30 days of the date of the attached cover letter. <br /> VII. SAMPLING ACTIVITIES <br /> No sampling was conducted during this inspection. <br /> VIII. CONCLUSIONS/DISCUSSIONS WITH OPERATOR <br /> Overall the facility had very few violations with the exception of the pending tank assessment issue. <br /> The 90-day Hazardous Waste Storage Area was well maintained. Pilkington could reduce the <br /> amount of hazardous waste generated by referencing DTSC fact sheet on the Management of Empty <br /> Containers, since some empty containers are being managed as hazardous waste. Training plans <br /> and records were well maintained on an Access database. Labeling and management of containers <br /> was well done. Dr. Wang was very informative on the various procedures at the plant. <br /> IX. ATTACHMENTS <br /> Attachment A: Summary of Violations issued on November 20, 2003 <br /> Attachment B: Pilkington Inspection Photographs, taken on November 19-20, 2003 <br /> Attachment C: DTSC letter to Dr. Wang dated December 23, 2003 <br /> Attachment D: Dr. Wang response letter dated January 6, 2004 <br /> Attachment E: DTSC Fact Sheets <br /> �j <br /> Step Binning Date:a- Zcy-) <br /> Hazardous Substances Scientist <br />