My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAVY
>
1443
>
2200 - Hazardous Waste Program
>
PR0220083
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:50:47 PM
Creation date
11/1/2018 12:40:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0220083
PE
2254
FACILITY_ID
FA0001542
FACILITY_NAME
VIKTRON EXPRESS
STREET_NUMBER
1443
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
16330017
CURRENT_STATUS
02
SITE_LOCATION
1443 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NAVY\1443\PR0220083\COMPLIANCE INFO 1990 - 2006.PDF
QuestysFileName
COMPLIANCE INFO 1990 - 2006
QuestysRecordDate
7/12/2018 4:49:25 PM
QuestysRecordID
3928087
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
258
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
57 66265.195(x) Failed to conduct daily inspection of tanks for <br />following: discharge control equipment, corrosion, releases, <br />monitoring and leak detection data, construction materials and <br />secondary containment areas, and level of waste in uncovered tanks. <br />( GOR) <br />58 66265.195(b) Failed to inspect cathodic protection systems (if <br />present) and sources of impressed current as appropriate. (GOR) <br />5966265.196 Failed to remove from service immediately a tank system or <br />— secondary containment system that had leaked or spilled. (GOR) <br />60 66265.197 During closure of tank system, failed to remove or <br />decontaminate all waste residues, contaminated tank system, sails, and <br />manage them as HW. (GOR) <br />61 66265.198(a) Stored or treated in tanks ignitable or reactive waste so <br />as to cause the waste to ignite or react. (GOR) <br />6266265.198(b) Failed to comply with buffer zone requirements for tanks <br />containing ignitable or reactive wastes per NFPA "Flammable and <br />Combustible Liquids Code. (GOR) <br />6366265.199(x) Stored incompatible wastes in same tank without complying <br />with 66251.17(b). (GOR) <br />64 66265.199(b) Placed HW in non -decontaminated tanks that previously <br />held an incompatible waste or material without complying with <br />66251.17(b). (GOR) <br />Ignitable, Reactive or Incompatible Wastes <br />NOTE: The following requirement applies to generators per <br />66265.177(a) for containers and 66265.199(x)&(b) for tanks. <br />65 66265.17(b) Failed to conduct transfer, storage, treatment, or <br />disposal of ignitable or reactive wastes / mixture or commingling of <br />incompatible wastes/materials to prevent: <br />(1) Generation of extreme heat or pressure, fire or explosion, <br />or violent reaction. <br />(2) Production of uncontrolled toxic mists, fumes, dusts or <br />-� gases to threaten human health or environment. <br />(3) Production of uncontrolled flammable fumes or gases to pose <br />risk of fire or explosions. <br />(4) Damage to structural integrity of HW containment devices. <br />(5) Threat to human health or the environment. (GOR) <br />7 <br />