My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NOWELL
>
26200
>
2200 - Hazardous Waste Program
>
PR0513888
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/9/2019 11:43:55 AM
Creation date
11/1/2018 1:17:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0513888
PE
2220
FACILITY_ID
FA0009531
FACILITY_NAME
UFP Thornton LLC
STREET_NUMBER
26200
STREET_NAME
NOWELL
STREET_TYPE
Rd
City
Thornton
Zip
95686
CURRENT_STATUS
01
SITE_LOCATION
26200 Nowell Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\N\NOWELL\26200\PR0513888\COMPLIANCE INFO 1989 - 2015.PDF
QuestysFileName
COMPLIANCE INFO 1989 - 2015
QuestysRecordDate
11/21/2017 12:29:48 AM
QuestysRecordID
3732620
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
211
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Yes No Comment <br /> 90 Day Acylation in Tanks (cont:) <br /> (Section 66262.34) <br /> If a double--walled tank, is the double-walled <br /> tank: [66265.193(e) (3)-] <br /> (A) Designed as an integral structure so that <br /> any release from the inner tank is contained <br /> by the outer shell? <br /> (B) If metal, protected from corrosion of the <br /> primary tank interior and the external surface <br /> of the outer shell? <br /> (C) Provided with built-in, continuous lead <br /> detection system capable of detecting a release <br /> within 24 hrs or ASAP, unless otherwise <br /> approved by the Department? <br /> Is all ancillary equipment provided with full <br /> secondary containment (e.g. , trench, jacketing, <br /> double-walled piping) except for the following? <br /> [66265.193(f)-] <br /> (1) Abovnd piping that is visually <br /> inspected daily. <br /> (2) Welded flanges, joints and <br /> connections that are visually <br /> inspected daily. <br /> (3) 5eal.less or magnetic coupling pumps <br /> and sealless valves that are visually <br /> ;aspected daily. <br /> (4) sized aboveground piping <br /> systems with automatic shut-off devices <br /> that are visually inspected daily. <br /> Tank Repair, Contairmient, or Closure: <br /> If the generator did not satisfy the requirements <br /> of sub-sections 66265.196(f) (2-4) (see below) , <br /> was the tank closed in accordance with sec.-tion <br /> 66265.197? [66265.196(f) (1) ] <br /> If the cause of the release was a spill that did <br /> not damage the integrity of the system, was the <br /> waste removed and wry repairs made before <br /> returning to service? [66265.196(f) (2) ] <br /> If the cause of the release was a leak from the <br /> primary tank system into the secondary tank <br /> system, was the system repaired before returning <br /> to service? (66265.196(f) (3) ] <br /> Revised 7/15/91 Page 16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.