Laserfiche WebLink
• <br />D. <br />Results of Testing/Servicing <br />Software Version Installed: 32£x.01 <br />Com lete the <br />followin <br />checklist: <br />® Yes <br />❑ Ne <br />Is the audible alarm operational? <br />® Yes <br />❑ No' <br />❑ No' <br />Is the visual alarm operational? <br />terfere with their proper <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />so that other equipment will not in <br />Yes <br />® Yes <br />❑ No" <br />Were all sensors installed at lowest point of secondary containment and positioned <br />® <br />operation? <br />relayed to a remote monitoring station, is all communications equipment (e.g., modem) operations <br />El Yes <br />❑ No' <br />® N/A <br />If alarms are <br />turbine automaticashutdnif the itcontainmenttem etects a leak, <br />Forprurizedpipingsytems,esthe ppositia shut-down?(Check all that apply)SumplTre ch <br />® Yes <br />[I No* <br />E] N/A <br />op which sensors <br />Sensors; ®Dispenser Containment Sensors. <br />failure/disconnection? 0 Yes; (3 No <br />Did you confirm positive shut -down due to leaks g_nd sensor <br />tank overfill warning device (Le., mechanical overfill prevention valve is <br />® Yes <br />❑ No' <br />For tank systems that utilize the monitoring system as the primary <br />y? <br />visible and audible at the tank fill points) and operating properly? If so, at what percent of tank capacity <br />❑ N/A <br />installed), is the overfill warning alarm <br />does the alarm trigger? 90% <br />sensors, probes, or other equipment replaced and list the manufacturer name <br />❑ Yes <br />® No <br />Was any monitoring equipment replaced? If yes, identify specific <br />and model for ail replacement parts in Section E, below. <br />dry systems? (Check all that apply) <br />®Yes" <br />❑ No <br />Was liquid found inside any secondary containment systems designed as <br />describe causes in Section E, below. <br />® Yes <br />❑ No' <br />❑ Product; ® Water. If yes, <br />Was monitoring system set-up reviewed to ensure proper Settings? Attach set up reports, if applicable <br />® Yes <br />❑ No' <br />Is all monitoring equipment operational per manufacturer's specifications? <br />• In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. <br />Comments: WATER FOUND IN 87 STP SUMP. WATER FOUND IN 89 FILL SUMP. <br />WATER REMOVED BY TESTER AND LEFT ON SITE IN DRUM <br />FILL LIDS MUST BE REMOVED IN ORDER TO DO OVERFILL ALARM TEST. THIS TAKES ABOUT <br />2 HRS OF TIME EXTRA ON SITE. OPW FILL LIPS <br />Monitoring System Certification Page 2 of 4 2/21/07 <br />