My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 1:43:23 PM
Creation date
11/1/2018 4:00:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />HARDY'S GAS STATION <br />16 E HARDING WAY STOCKTON <br />February 23 2016 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />104 <br />CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br />UST Tank Information forms for all three tanks are not current in CERS. <br />- The tank form for the 87 tank incorrectly states the vent piping is double walled and that there are no vapor recovery <br />lines. <br />- The tank form for the 91 tank incorrectly states the vent piping is double walled and that there are no vapor recovery <br />lines. <br />- The tank form for the diesel tank incorrectly states the vent piping is double walled and that there are no vapor <br />recovery lines. It also states that the contents are midgrade fuel instead of diesel. <br />Any change of information must be updated in CERS within 30 days of the changes. Immediately log into CERS, <br />update the required information, and submit for review by the EHD. <br />This is a Class II violation. <br />106 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The response plan is not current and/or not approved by the EHD. Section V of the response plan has not been <br />completed. The response plan must be uploaded to the California Environmental Reporting System (CERS). <br />Immediately log into CERS, upload the completed form, and submit for review by the EHD. Ensure a copy is available <br />for inspection at any time. <br />This is a minor violation. <br />113 <br />CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br />Annual monitoring system certification, leak detector testing, and spill container testing was performed on February <br />17, 2015 and a test report was submitted on April 6, 2015, one month late. A copy of the test report must be <br />submitted within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports <br />are performed in a timely manner. <br />This is a minor violation. <br />126 <br />HSC 25404(e)(4) Failed to report program data electronically. <br />The UST Monitoring Site Plan was not submitted to the the California Electronic Reporting System (CERS). <br />Beginning January 1, 2014, all businesses are required to submit all new (or any changes to existing) UST <br />information, including: UST Monitoring Site Plan, UST Certification of Financial Responsibility, UST Response Plan, <br />UST Owner/Operator Written Agreement (if applicable), UST Letter from Chief Financial Officer, and Owner Statement <br />of Designated UST Operator Compliance online to the CERS at http://cers.calepa.ca.gov. Be sure to include any <br />other relevant activities and required fields. <br />This is a minor violation. <br />Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.