COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 1:43:23 PM
Creation date
11/1/2018 4:00:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OAau tN•..0 <br />-'� '•° SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />h {i <br />1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br />/ Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br />Facility Name: <br />`�. <br />Inspection Date: <br />_No )li LR(k <br />❑ mechanical Model: <br />tis 12 2j(,- 15 <br />Facility Address: <br />Ei. .0 <br />%COM I l�Tt � tet/ <br />Servicb Req est #: <br />S <br />Onstt Service Tech ame: <br />Leak detector <br />ICC Service Technician/Installer Exp. Date: <br />Manufacturer Training: <br />Title: <br />❑ electronic Serial #: <br />❑ <br />❑ line test programmed <br />SERVICE <br />`�. <br />Leak detector <br />❑ <br />❑ mechanical Model: <br />/ <br />❑ electronic Serial #: <br />❑ line test programmed <br />❑ <br />Leak detector <br />❑ <br />❑ mechanical Model: <br />Title: <br />❑ electronic Serial #: <br />❑ <br />❑ line test programmed <br />sensor <br />❑ <br />❑ positive shutdown Model: <br />❑ fail safe Serial #: <br />❑ NA <br />❑ <br />sensor <br />❑ <br />❑ positive shutdown Model: <br />❑ fail safe Serial #: <br />❑ <br />❑ NA <br />❑ <br />sensor <br />❑ <br />❑ positive shutdown Model: <br />❑ fail safe Serial #: <br />❑ NA <br />❑ <br />Drop tube with mechanical overfill at 95% <br />Drop tube with mechanical overfill at 95% <br />HO—Overfill <br />prevention (see LG letter 150-1) <br />�fl This UST facility is APPROVED to operate <br />SERVICE <br />`�. <br />Spill bucket .6minimum 5 gallon <br />USl <br />1 hour hydrostatic ❑ Incon TS -STS <br />/ <br />❑ Caldwell System ❑ Other <br />Spill bucket ❑ minimum 5 gallon <br />❑ <br />❑ 1 hour hydrostatic ❑ Incon TS -STS <br />6 <br />❑ Caldwell System ❑ Other <br />Title: <br />Primary piping testing at: <br />❑ <br />psi <br />minutes <br />Secondary containment testing for: <br />UDC(s) Piping <br />Sump(s) UST(s) <br />❑ <br />Testing for the above components are next due by: <br />Note. Please be aware that 21 containment components are required to be tested upon <br />installation, 6 months after, and every 36 months thereafter. <br />❑ <br />Cold start of monitoring panel <br />❑ <br />Corrosion protection <br />❑ <br />Other: see below <br />❑ This UST facility is NOT APPROVED to operate <br />©(SSI O iese <br />S G cwt 1%' t QiJ1I MmgVVt, <br />en i 'k:.. T <br />e z I <br />S 4 IIS, <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br />EHD Insp / i /� <br />jl l7'� Y1 <br />6 <br />Re d B <br />Title: <br />EHD 23-04 UST SERVICE REQUEST INSPECTION REPORT <br />Rev 4/30/12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.