My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 1:43:23 PM
Creation date
11/1/2018 4:00:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Integrated solution for centralized, <br />single system site monitoring. <br />Standard Models <br />Console Form Number: 848290-022 <br />Description: TLS -350 Plus monitoring console with integral printer <br />Console Form Number: 848290-002 <br />a <br />Description: TIS -350 Plus monitoring console without integral <br />printer <br />Console Form Number: 848291-021 <br />Description: TLS -350 Plus PC version without printer, keyboard or display <br />TLS -350 Plus Interface Modules <br />The TLS -350 Plus monitoring console contains three compartments in which individual interface modules can be installed. Interface modules <br />may be factory -installed in the console upon initial ordering, or ordered separately as spare modules to expand an existing system. <br />Form No. <br />Factory <br />Installed <br />Modules Description <br />Feature Compatibility (where applicable) <br />LOW-POWER COMPARTMENT (Limit eight per ca isoFa, a c'ss otherwise noted) <br />329356-002 Four -Input Probe Interface Module (Maximum three per <br />Series 8473 0.1 GPH Magnetostrictive Probe <br />console. Includes terminal connector for one ground <br />Series 8463 0.1 GPH Mag Plus Magnetostrictive Probe <br />temperature thermistor for the volumetric line leak detector). <br />329358-001 Eight -Input Interstitial/Liquid Sensor <br />Series 7943 Interstitial Sensor for Fiberglass Tanks and <br />Interstitial Sensor for Steel Tanks <br />Series 7943 Piping Sump Sensor <br />Series 7943 Hydrostatic Sensor <br />329357-001 Five -Input Vapor Sensor Interface Module <br />Series 7943 Vapor Sensor <br />329399-001 Five -Input Groundwater Sensor Module <br />4SITE Series 7943 Groundwater Sensor <br />329956-001 Eight -Input Type A Sensor Interface Module <br />4SITE Series 7943 Discriminating Interstitial Sensor <br />329950-001 Six -Input Type B Sensor Interface Module <br />4SITE Series 7943 Discriminating Dispenser <br />330843-001 Six-InputPressurized Line Leak Interface <br />Series 8484 Pressurized Line Leak Detection System <br />Module (One per console) <br />Requires TLS -350 Plus version 7.0 or higher software <br />329356-004 Eight -Input Smart Sensor Module <br />Series 857080 Mag Pan Sump Sensor <br />Series 857280 Vacuum Sensor <br />332250-001 Seven Input Smart Sensor Module <br />Same as above <br />with Embedded Pressure Sensor <br />HIGH-POWER COMPARTMENT (Limit eight per console, unless otherwise rioted) <br />329359-001 Four -Relay Output Interface Module <br />329360-001 Two-Input/Two-Relay Output Interface Module <br />329999-001 Pump Sense Interface Module <br />Accepts up to four inputs <br />330374-001 Three -Output Pressurized Line Leak ° <br />Series 8484 Pressurized Line Leak Detection System <br />Controller Interface Module (Two per console) <br />Requires TLS -350 Plus version 7.0 or higher software <br />COMMUNICATIONS COMPARTMENT (Limit three per console, unless otherwise noted) <br />330149-002 SiteFax Interface Module <br />Allows hookup to most remote facsimile, modem or teletype <br />equipment. Requires TLS -350 Plus version 3.0 or higher software. <br />330586-001 RS -485/232 Dual Port Communications Module (Slot 4 only) <br />330148-001 RS -232 Interface Module with Auxiliary Port <br />Provides two 25 -pin D -connectors for data transmission to <br />P.O.S. terminal, printing device or computer <br />329362-001 RS -232 Interface Module <br />Provides a 25 -pin D -connector for data transmission to <br />P.O.S. terminal, printing device, or computer <br />330000-001 Remote Printer Interface Module + <br />Provides a 25 -pin D -connector for data transmission <br />to a remote serial printer <br />330883-001 WPLLD Communications Module <br />(Maximum one per console) <br />330020-425 Ethernet —TCP/IP Communications module <br />Provides connectivity to local and wide area networks (LAN/WANS) <br />Specifications <br />For more information call <br />Operating Temperal ira i r. 32'F to 118'F (0'C to 45°C) <br />1-888-861-7942 <br />Storage Temperature Hang, 15'F to 118'F (10'G to 451C) <br />f <br />f <br />®p�� ®VO 20 6 Vee$er-Root Company 125 Powder Forest Drive • Simsbury, CT 06070. • IPJ rA <br />iii V <br />T ` <br />` <br />® Telephont:860-651-2700 <br />Fax:860-651-2719 • www.veeder.com <br />^}E <br />im ioa-'n nmr nc-icne-r m n -..c 1-1— <br />smnn <br />!f <br />.._.-�♦L <br />f <br />fn <br />- F ' ! ♦ ; •�!,pr. ♦- <br />`!!♦. +i <br />•RYIIjM: <br />- -, 5 + /-.y. , <br />f Z t !1r 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.