My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 1:43:23 PM
Creation date
11/1/2018 4:00:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
or �. r <br />SWRCB, January 2006 <br />Spill Bucket Testing Report Form <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. <br />1. FACILITY INFORMATION <br />Facility Name: HARDY'S GAS & FOOD <br />I Date of Testing: 2/21/2017 <br />Facility Address: 16 E. HARDING WAY <br />STOCKTON , CA <br />l 87 - EAST <br />Facility Contact: HARDEEP <br />Phone: 466-9516 <br />4 DIESEL <br />Date Local Agency Was Notified of Testing :1/30/2017 <br />❑ Direct Bury <br />®Contained in Sump <br />Name of Local Agency Inspector ('(present during testing): <br />STACY RIVERA MAR <br />2. TESTING CONTRACTOR INFORMATION <br />11 <br />Company Name: AFFORDA TEST 416 211 Street Galt, CA 95632 (209) 744-01 <br />Technician Conducting Test: ❑ Lyle D. Nimmo ® Zane A. Nimmo ❑ David A. Winkler ❑ Felix G. Ramirez <br />5249115 -UT 5263322 -UT 5263373 -UT 5273934 -UT <br />Credentials': ® ICC Service Tech. ® SWRCB Tank Tester <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br />Test Equipment Used: TAPE MEASURE, H2O Equipment Resolution: 1/16" <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />l 87 - EAST <br />2 87 - WEST <br />3 91 <br />4 DIESEL <br />Bucket Installation Type: <br />❑ Direct Bury <br />®Contained in Sump <br />❑ Direct Bury <br />®Contained in Sump <br />❑ Direct Bury <br />® Contained in <br />Sump <br />❑ Direct Bury <br />® Contained in <br />Sum <br />Bucket Diameter: <br />1 1 <br />11 <br />I 1 <br />11 <br />Bucket Depth: <br />13 1/4 <br />14 1/4 <br />13 1/4 <br />11 1/8 <br />Wait time between applying <br />vacuum/water and start of test: <br />Test Start Time (Ti): <br />1000 <br />1000 <br />1000 <br />1000 <br />Initial Reading (RI): <br />11 1/2 <br />11 1/2 <br />11 1/2 <br />11 1/8 <br />Test End Time (TF): <br />1100 <br />1100 <br />1100 <br />1100 <br />Final Reading (RF): <br />11 1/2 <br />11 1/2 <br />11 -- <br />11 1/8 <br />Test Duration (TF — TI): <br />HR <br />HR <br />HR <br />HR <br />Change in Reading (RF - R,): <br />0 <br />0 <br />-1/2 <br />0 <br />Pass/Fail Threshold or <br />Criteria: <br />Test Result: <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ® Fail <br />® Pass ❑ Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />91 Spill bucket failed at bottom. To be repaired and retested by others. <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature �` Date: 2-21-17 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />
The URL can be used to link to this page
Your browser does not support the video tag.