My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/18/2023 1:43:23 PM
Creation date
11/1/2018 4:00:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231136
PE
2361
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
01
SITE_LOCATION
16 E HARDING WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
291
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br />MONITORING SYSTEM CERTIFICATION MAR I 0 2G1� <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code <br />of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or reg ht6stU9rN2�d-Rir�TAL H EALTH <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the <br />l,� T F NT <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 day''s��oftest 11a��e. <br />A. General Information <br />Facility Name: HARDY'S GAS & FOOD Bldg. No.: <br />Site Address: <br />16 E. HARDING WAY City: STOCKTON <br />Zip: 95204 <br />Facility Contact Person: HARDEEP Contact Phone No.: ( ) <br />Make/Model of Monitoring System: VEEDER ROOT TLS -350 Date of Testing/Servicing: 2/21/2017 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br />Tank ID: 87 <br />Tank Size: <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />Tank Size: <br />Model: <br />® In -Tank Gauging Probe. Model: MAG I <br />® Annular Space or Vault Sensor. <br />Model: <br />4 0 9 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />2 0 8 <br />❑ Piping Sump /Trench Sensor(s). <br />Model: <br />® Fill Sump Sensor(s). <br />Model: <br />2 0 8 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />RJ -CPT <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />90% <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and <br />model in Section E on Page 2). <br />Tank ID: DIE <br />Tank Size: <br />Tank ID: 91 <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />® In -Tank Gauging Probe. <br />Model: MAG I <br />® Annular Space or Vault Sensor. <br />Model: <br />4 0 9 <br />® Annular Space or Vault Sensor, <br />Model: SHARED W/ DIE <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />2 0 8 <br />® Piping Sump / Trench Sensor(s). <br />Model: 2 0 8 <br />® Fill Sump Sensor(s). <br />Model: <br />2 0 8 <br />® Fill Sump Sensor(s). <br />Model: 2 0 8 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />RJ -CPT <br />® Electronic Line Leak Detector. <br />Model: RJ -CPT <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />90% <br />® Tank Overfill / High -Level Sensor. <br />Model: 90% <br />❑ Other (specify equipment type and model <br />in Section E on Page 2). <br />❑ Other (specify equipment type and <br />model in Section E on Page 2). <br />Dispenser ID: I / 2 <br />Dispenser ID: 3 / 4 <br />® Dispenser Containment Sensor(s). <br />Model: <br />2 0 8 <br />® Dispenser Containment Sensor(s). <br />Model: '_ 0 S <br />® Shear Valve(s). <br />M Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5 / 6 <br />Dispenser ID: 7 / 8 <br />® Dispenser Containment Sensor(s). <br />Model: <br />2 0 8 <br />M Dispenser Containment Sensor(s). <br />Model: 2 0 8 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9 / 10 <br />Dispenser ID: <br />❑ Dispenser Containment <br />® Dispenser Containment Sensor(s). <br />Model: <br />2 0 8 <br />Sensor(s). <br />Model: <br />® Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): ZANE NIMMO Signature: <br />Certification No.: A28446 License No: 04-1676 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 4162 nd STREET GALT, CA 95632 Date of Testing/Servicing: 2/21/2017 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.