Laserfiche WebLink
3 <br />Appendix VI <br />MONITORING SYSTEM CERTIFICATION MAR 16 2016 <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of ti EntZA <br />or <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared fr -u3n nTn none r <br />r <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: VALLEY SERVICE STATION ARCO Bldg. No.: <br />Site Address: 16 EAST HARDING LANE <br />Facility Contact Person: <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 <br />City: STOCKTON <br />Zip: 95204 <br />Contact Phone No.: (209) 466-9516 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br />Date of Testing/Servicing: 2-23-2016 <br />Tank ID: 87 <br />Tank ID: DIE <br />N In -Tank Gauging Probe. <br />Model: MAG 1 <br />N In -Tank Gauging Probe. Model: MAG 1 <br />N Annular Space or Vault Sensor. <br />Model: <br />409 <br />N Annular Space or Vault Sensor. <br />Model: 409 <br />N Piping Sump /Trench Sensor(s). <br />Model: <br />208 <br />N Piping Sump / Trench Sensor(s). <br />Model: 208 <br />N Fill Sump Sensor(s). <br />Model: <br />208 <br />N Fill Sump Sensor(s). <br />Model: 208 <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />N Electronic Line Leak Detector. <br />Model: <br />CPT <br />N Electronic Line Leak Detector. <br />Model: CPT <br />N Tank Overfill / High -Level Sensor. <br />Model: <br />90% <br />N Tank Overfill / High -Level Sensor. <br />Model: 90% <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: 91 <br />Tank ID: <br />N In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />❑ In -Tank Gauging Probe. <br />Model: <br />N Annular Space or Vault Sensor. <br />Model: <br />409 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />N Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />N Fill Sump Sensor(s). <br />Model: <br />208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />N Electronic Line Leak Detector. <br />Model: <br />CPT <br />❑ Electronic Line Leak Detector. <br />Model: <br />N Tank Overfill / High -Level Sensor. <br />Model: <br />90% <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />DispenserlD: 1-2 <br />Dispenser ID: 34 <br />N Dispenser Containment Sensor(s). <br />Model: <br />208 <br />N Dispenser Containment Sensor(s), <br />Model: 208 <br />N Shear Valve(s). <br />N Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />N Dispenser Containment Sensor(s). <br />Model: <br />208 <br />N Dispenser Containment Sensor(s). <br />Model: 208 <br />N Shear Valve(s). <br />N Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />DispenserlD: 9-10 <br />Dispenser ID: <br />❑ Dispenser Containment <br />N Dispenser Containment Sensor(s). <br />Model: <br />208 <br />Sensor(s). <br />Model: <br />N Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />'If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): N System set-up N Alarm history report <br />Technician Name (print): DAVEW INKLER <br />Signature: <br />Certification No.: 5273934 -UT License No: 08-1740 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 416 2nd STREET GALT, CA 95632 Date of Testing/Servicing: 2-23-2016 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />