Laserfiche WebLink
Page 16 of 21 <br /> Calsdence <br /> Environmental <br /> Glossary of Terms.and Qualifiers <br /> Y. aboratorles, Inc. <br /> Work Order Number. 08-10-1847 <br /> clualifieI: l-efi nitio n <br /> See applicable analysts comment. <br /> 1 Surrogate compound recovery was out of control due to a required sample dilution, <br /> therefore, the sample data was reported without further clarification. <br /> 2 Surrogate compound recovery was out of control due to matrix Interference. The <br /> associated method blank surrogate spike compound was in control and, therefore, the <br /> sample data was reported without further clarification. <br /> 3 Recovery of the Matrix Spike (MS)or Matrix Spike Duplicate (MSD) compound was out of <br /> control due to matrix interference. The associated LCS and/or LCSD was In control and, <br /> therefore, the sample data was reported without further clarification. <br /> 4 The MS/MSD RPD was out of control due to matrix interference. The LCSILCSD RPD <br /> was In control and,therefore,the sample data was reported without further clarification. <br /> 5 The PDSIPDSD associated with this batch of samples was out of control due to a matrix <br /> Interference effect. The associated batch LCSILCSD was In control and, hence, the <br /> associated sample data was reported with no further corrective action required. <br /> A Result Is the average of all dilutions, as defined by the method. <br /> B Analyte was present in the associated method blank. <br /> C Analyte presence was not confirmed on-primary column. <br /> E Concentration exceeds the calibration range. <br /> H Sample received and/or analyzed past the recommended holding time. <br /> J Analyte was detected at a concentration below the reporting limit and above the <br /> laboratory method detection limit. Reported value is estimated. <br /> ME LCS Recovery Percentage Is within LCS ME Control Limit range. <br /> N Nontarget Analyte, <br /> ND Parameter not detected at the indicated reporting limit. <br /> Q Spike recovery and RPD control limits do not apply resulting from the parameter <br /> concentration In the sample exceeding the spike concentration by a factor of four or <br /> greater. <br /> U Undetected at the laboratory method detection limit. <br /> X %Recovery and/or RPD out-of-range. <br /> Z Analyte-presence was not confirmed by second column or GOIMS analysis. <br /> 7444 Lincoln Way,Garden drove, CA 92841.1427 • TEL:(7t4)895-5494 • FAX. (714)894-7501 <br />