My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ARGONAUT
>
1819
>
2900 - Site Mitigation Program
>
PR0508343
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2018 1:27:56 AM
Creation date
11/1/2018 4:29:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0508343
PE
2960
FACILITY_ID
FA0008041
FACILITY_NAME
JOHN TAYLOR - STOCKTON
STREET_NUMBER
1819
Direction
S
STREET_NAME
ARGONAUT
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16320008
CURRENT_STATUS
01
SITE_LOCATION
1819 S ARGONAUT ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• MONITORING AND REPORTING PfWAM NO. R5-2009-0857 • 3 - <br />JOHN TAYLOR FERTILIZERS CO.. INC., WILBUR-ELLIS COMPANY <br />STOCKTON FACILITY SAN JOAQUIN COUNTY <br />1. Conduct monitoring and reporting in compliance with the following specifications. <br />2. (a) As shown on Figure 1, there are seven (7) existing shallow groundwater <br />monitoring wells (MW -1, MW -2, MW -3, MW -4, MW -5, MW -6 and MW -7). <br />Additional deep groundwater monitoring well(s) are been considered to be <br />installed. The groundwater monitoring program for the seven shallow monitoring <br />wells and any shallow wells installed for routine groundwater monitoring <br />subsequent to the issuance of this MRP, shall be sampled semi-annually as <br />shown in Table 1. All wells shall be monitored semi-annually for Depth to <br />Groundwater. Wells that must be sampled semi-annually shall be sampled <br />during the first and third quarters. <br />Table 1. <br />Groundwater Monitoring Schedule for Groundwater Monitoring Wells <br />Constituents <br />EPA Analytical <br />Method <br />Maximum <br />Practical <br />uantitation Limi <br />Monitoring Wells <br />Depth to Groundwater <br />--- <br />0.01 foot <br />All <br />Total Oxidizable Nitrogen <br />353.2 <br />1.0 mg/I <br />All <br />olatile Organic Compounds <br />8260B <br />0.5 µg/12 <br />All <br />1,2,3-trichloropropane <br />SRL 524M -TCP <br />0.005 pg/I <br />All <br />'Chloride <br />300.0 <br />1 mg/L <br />All <br />Bromaci1 <br />632 <br />1 µg/I <br />All <br />For nondetectable results. All concentrations betWeen the Method Detection Limit and the <br />Practical Quantitation Limit shall be reported as trace. <br />Detection limits for bromomethane, dichlorodifluoromethane, Freon 113 and MTBE are 1 pg/I <br />(b) In addition, any deep monitoring wells (approximately 50 feet bgs) installed <br />subsequent to the issuance of this MRP, shall also be sampled semi-annually for <br />at least two consecutive sampling events for constituents shown in Table 2. If all <br />constituents in an analytical suite are not detected in two consecutive semi- <br />annual events in the deep monitoring well(s), that analytical suite may be <br />removed from the monitoring schedule for that well, and shall then follow the <br />schedule as shown in Table 1 subject to Central Valley \/Vater Board staff's <br />concurrence. Sample collection and analysis shall follow standard EPA protocol. <br />rlu <br />C:7 <br />D <br />is <br />
The URL can be used to link to this page
Your browser does not support the video tag.