Laserfiche WebLink
California Code of Regulations (CCR) Section 2637(a) Secondary containment <br /> systems installed prior to January 1, 2001 shall be tested by January 1, 2003 and every 36 <br /> months thereafter. <br /> -+Secondary containment testing was not completed by January 1, 2003. <br /> CCR 2711 (b)The owner or operator shall inform the local agency of any changes to the <br /> information provided in accordance with subsection(a)within 30 calendar days unless <br /> required to obtain approval before making the change. <br /> -+Current owner information is not in the facilityfile. There may have been a change of <br /> ownership because Mary Lou Pontes stated she was going through a divorce. <br /> CCR 2632(b) Owners or operators of underground storage tanks subject to this section <br /> shall implement a monitoring program approved by the local agency and specified in the <br /> underground storage tank operating permit. <br /> -+A monitoring and response plan has not been submitted to this ofce for approval. <br /> CCR 2712(i)A copy of the permit and all conditions and attachments, including <br /> monitoring plans, shall be retained at the facility. <br /> -+A monitoring and response plan was not found at the facility on July 1, 2002 during a <br /> routine inspection. <br /> Hazardous Waste Violations <br /> CCR 66262.12(a) Except as specified in (d), a generator shall not treat, store,dispose or <br /> transport or offer for transportation,hazardous waste without having received an <br /> Identification Number. <br /> -->This facility does not have an EPA ID number. <br /> CCR 66265.32(c) All facilities shall be equipped with the following, unless it can be <br /> demonstrated to the Department that none of the hazards posed by waste handled at the <br /> facility could require a particular kind of equipment specified below:... (c)portable fire <br /> extinguishing equipment, fire control equipment(including special extinguishing <br /> equipment, such as that using foam, inert gas,or dry chemicals), spill control equipment, <br /> and decontamination equipment;... <br /> ->This facility does not have spill control equipment. <br /> CCR 66262.34(d)(2)The generator complies with the requirements of subdivisions(d), <br /> (e) and(f) of section 262.34 of Title 40 of the Code of Federal Regulations. (Attachment <br /> 15) <br /> -+This facility did not have hazardous waste emergency information posted by their <br /> telephones. <br /> 6 <br />