My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
30600
>
2300 - Underground Storage Tank Program
>
PR0231998
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 9:20:38 AM
Creation date
11/2/2018 10:38:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231998
PE
2381
FACILITY_ID
FA0003643
FACILITY_NAME
CHEM-AWAY, INC
STREET_NUMBER
30600
Direction
S
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25310015
CURRENT_STATUS
02
SITE_LOCATION
30600 S CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION-FORM B <br /> H <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLO E <br /> ONE ITEM F-12 INTERIM PERMIT ❑ 4 AMENDED PERMIT 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED ' <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.# aAa- B. MANUFACTURED BY: <br /> We— <br /> C. DATE INSTALLED(MODAY/YEAR) UN-, D. TANK CAPACITY IN GALLONS: I <br /> II.TANK CONTENTS IF A-1 IS MARKED.COMPLETE ITEM C. <br /> A 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. le REGUUR UNLEADED Q 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑ :PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 2 PETROLEUM ❑ BO EMPTY w 1 PRODUCT ❑ 1C MDGRAOE UFLLEADEDn��'I 5 JET FUEL ❑ 6 M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE El LEADED u 99 OTHER(DESCRIBE W ITEM D.BELOW) <br /> D. IF(At)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B.AND C.AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (P11m1YTanW ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER UNED ❑ 2 ALKYD UNING ❑ 3 EPDXY LINING ❑ 4 PHENOUC LINING <br /> LINING OR ❑ 5 GLASS LINING u 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLlWITH 10D% METHANOL? YES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION B1 NONE E] 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,BTC. SPILL CONTAINMENT NSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE YES_ NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A W-1 <br /> SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND Al U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A 5 ALUMINUM A U B CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODICPROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION 1 KEaHNMGu UNE LEAK 2 ME T414NESs 3 CONNNUWS IN1E0.5111VL 4 ELEG1RdVIC UNE s AUf01MiIC MNP <br /> ❑ OERCTOR ❑ TESTMU ❑ MONTORMG ❑ UAK OEiECTW ❑ 9XI1I10NRH ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 q CO CIU TIONUAL ORY ❑ 3 MONITORING ❑ 4 GAUL NG AUTOMATIC TANK ❑ 5 MONITORINGTER ❑6 TEGROUND <br /> ❑ 7 NRUINTERSTITIAL ❑ 8SIR ❑10 MONTHLY TANK <br /> ❑ 95 UNKNOWN 99 OTHERpEGMOTOTANK GAUGING TESTING <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE N-PLACE) <br /> 1.ESTlW,P LATE LAST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF //ll L 3.WAS TANK FILLED WITH YES ❑ NO <br /> `t��_ SUBSTANCE REMAINING l� f- GALLONS INERT MATERIAL <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME //11 }� DATE/ Q <br /> (PRINTED551GNATURE) 4A/(IJ <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# ' n TANK# <br /> STATE I.D.# <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATNIN-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM-C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLAT IE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UV ,)GROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) .� FOR0034 <br />
The URL can be used to link to this page
Your browser does not support the video tag.