My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
30600
>
2300 - Underground Storage Tank Program
>
PR0231998
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2019 9:20:38 AM
Creation date
11/2/2018 10:38:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231998
PE
2381
FACILITY_ID
FA0003643
FACILITY_NAME
CHEM-AWAY, INC
STREET_NUMBER
30600
Direction
S
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
25310015
CURRENT_STATUS
02
SITE_LOCATION
30600 S CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> c'. <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B , <br /> I <br /> COMPLETE A SEPARATE FORM FO EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT n 6 TEMPORARY TANK CLOSURE ID B TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: T' Q <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A OWNERS TANK 1.D.# m14f, B. MANUFACTURED BY: Uu <br /> C. DATE INSTALLED(MO'DAYNEAR) Mue— D. TANK CAPACRY IN GALLONS: <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> 1 MOTOR VEHICLE FUEL ❑ 4 OIL S. C. Ia REGULAR UNLEADED 3 DIESEL ❑ 8 AVIATION GAS <br /> A lb PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY ❑ i PRODUCT El Ic MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE Q 2 LEADED ❑ 99 OTHER ryESCflIBE IN ffFM D.BFLOYl) <br /> D. IF(A1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF I DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR UNER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD WT FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INFERIOR ❑ I RUBBER LINED ❑�-�y 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR F-15 GLASS LINING 1 7L 6 UNLINED E] 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP O 2 COATING Q 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION � <br /> PROTECTION [:j2 <br /> 5 CATHODIC PROTECTION � 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E SPILL AND OVERFILL,MC. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE YES_ NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A 1 SUCTIN A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION Aul <br /> 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND u 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMMPPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER__Xff6>= <br /> D. LEAK DETECTION ❑1 Lacxuacu WE LEY( ❑2 INE 1NHIEESS F-13 CCIAMIWS NTERST ❑4 E3ECTRDND UNE ED <br /> 5 AUrOM m mw 99 OTHER <br /> OflECrOF TESLING Mp4T0RND TEM DETECTOR SNRWWX <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 gRECONCILIATIONAL ORY ❑ 3 MAONNIITORING ZE ❑ 4 GAUGING AUTOMATIC TANK ❑ 5 GROUND MONITORING F-1 ANNUALTANK <br /> 6 TESTING <br /> ❑ 7 MON TOR NPS G INTERSTITIAL ❑ 8 SIR ❑ 9 TANK L MANUAL ED 10 MONTHLY TANK ❑ 95 UNKNOWN ❑99 OTHER <br /> TESTING <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.E t DATE LAST USED(MO/DAY/YR) 2.ESTIMATED GUANRTY OF `{ GALLONS 3 WAS TAN WAS <br /> WITH YES ❑ NO� <br /> SUBSTANCE REMAINING MATERIAL <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAMEDATE/��f <br /> (PAINTED A SIGNATURE) AA04e fXy Cf41 XY <br /> LOCAL AGENCY USE ONLY THE STATE I.D.duMBER IS COMPOSED OF THE FOUR NUMBERS BELOW I <br /> COUNTY# JURISDICTION If FACILITY It TANK M <br /> STATE I.D.# © 111 a 19 1 /n/vZ� <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICAT^N-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLA .E THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UE' `GROUND STORAGE TANK REGULATIONS <br /> FORM B (6.95) lw FORD034"T <br />
The URL can be used to link to this page
Your browser does not support the video tag.