1976
>
2300 - Underground Storage Tank Program
>
PR0504061
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2024 2:44:10 PM
Creation date
11/2/2018 3:08:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504061
PE
2381
FACILITY_ID
FA0006064
FACILITY_NAME
NUNES HAY SERVICE
STREET_NUMBER
1976
Direction
N
STREET_NAME
UNION
STREET_TYPE
RD
City
MANTECA
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
1976 N UNION RD
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\wng
Supplemental fields
FilePath
\MIGRATIONS\U\UNION\1976\PR0504061\BILLING .PDF
QuestysFileName
BILLING
QuestysRecordDate
10/31/2017 9:47:22 PM
QuestysRecordID
3713196
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIft WATER RESOURCES CONTR�ARD ^ ' <br /> FORM 'S': UNDE ROUND STORAGE TION INFORMATION ® <br /> TANK AM <br /> TANK PERMIT APPLICATION _> <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING I ORMATION FOR EACH TANK. <br /> F-11 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> MARK ONLY <br /> ONE ITEM F-12 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑e TANK REMOVED 70 <br /> Ik..� }� FARM TANK-YES❑ NO -r- <br /> FACILITY/SITE <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 7L- �,1 I ° ' I�AJ '::SJ <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY cn <br /> 4N. <br /> A. OWNERS TANK ID B. MANUFACTURED BY: <br /> G <br /> CYEAR INSTALLED D. TANK CAPACITY IN GALLONS: U <br /> . y O v <br /> II. TANK CqNTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> B C. ❑ 1 UNLEADED LEADED ❑ 3 DIESEL <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL <br /> PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE/IN�ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF C.A.S.#: (V <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.N <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A.B,C,&D <br /> 10 EWALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER 09 UNKNOWN <br /> A.TYPE OF ❑ 99 OTHER <br /> SYSTEM 2 SINGLE LLED ❑ 4 SECONDARY CONTAINMENT <br /> STEEL/IRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ 8100%METHANOL COMPATIBLEFRP <br /> MATERIAL ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 APD ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C. INTERIORF-1 5 GLASS LINING UNLINED F-195 UNKNOWN <br /> LINING <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO 99 OTHER <br /> D.CORROSION ❑ I POLYETHLENEWRAP TAR OR ASPHALT ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFO��PLAST <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINEDTRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U ALUMINUM A U 6 CONCRETE A U 7 STEELCLADW/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A/U/9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> O <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 5 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUNDWATER MONITORING WELLS <br /> P 8 6 PRECISION TESTING P S 7 PRESSURE TESTING �P S - NONE P 8 95 UNKNOWN P S 99 OTHER <br /> 1. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> ESTIMATED QUANTITY OF 3. WAR TANK FILLED WITH <br /> 1. ESTIMATED DATE LAST USED(M /YR 2. SUBSTANCE REMAINING IN INERT MATERIAL? [:]YES [:] NO <br /> GALLONS <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> DATE <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) <br /> LOCAL AGENCY USE ONLY <br /> FACILITY ID# TANK ID# <br /> NTY k <br /> COUJURISDICTION# AGENCY# T7, <br /> APPROVED BY NA E ( PHONE#WITH AREA CODE <br /> CURRENT LOCAL AGENCY FACILITY IDM /D �/ Q o <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRAT NDATE <br /> CHECK# PERMIT AMOUNT SURCHARGE T. FEE CODE RECEIPT# BY: <br /> ft <br /> FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIE A FACILITY/SITE APPLICATION, FORM 'A',UNLESS AI RENT FORMA' HAS BEEN FILED S <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.