My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 11:29:01 AM
Creation date
11/2/2018 3:41:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\1405\PR0231485\BILLING 1987-1998.PDF
QuestysFileName
BILLING 1987-1998
QuestysRecordDate
5/11/2018 10:22:36 PM
QuestysRecordID
3890093
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�IFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VL UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD - 490-54a <br /> ❑ 1.CONTINUOUS ELECTRONIC MONITORING490-54b <br /> ®2.FLOAT AND CHAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE <br /> ❑ 4.NO DISPENSERS [199.OTHER(Specify):____________ <br /> PANEL MANUFACTURER: 49ass—LMODEL#: ------ 49as6. <br /> --- <br /> —— ------------'-- <br /> LEAK SENSOR MANUFACTURER: 490-50 1 MODEL#(S): 49x58 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑ a.YES ❑b.NO 490.59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ❑ a.YES ❑b.NO 49°60. <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑b.NO 490'61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. ® a.YES ❑b.NO 490L2 <br /> 2.UDC CONSTRUCTION IS ®1.SINGLE-WALLED ❑2.DOUBLE-WALLED 49040 <br /> IF DOUBLE WALLED: 490=s4a <br /> UDC INTERSTITIAL SPACE IS MONITORED BY �_I_LIQUID__-(]_2_PRESSURE [13.VACUUM -- <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑a.YES ❑b.NO 490-64b <br /> - - <br /> VIL PERIODIC SYSTEM TESTING <br /> ❑ <br /> —IELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 490-65. <br /> ____2._LEAK DETECTION(ELD)MUST BE PERFORMED_ PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REUIRED._L3 CCR¢2644.1)Q <br /> ® SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 49 6 <br /> ❑MIS BUCKETS ARE TESTED ANNUALLY. 49M7 <br /> VIII.RECORDKEEPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> ®Alarm logs 490 &a ®Visual Inspection Records 490.686 ❑Tank integrity testing results 490b8c <br /> ❑SIR testing results(and supporting documentation records). 49MIld ❑ Tank gauging results(and supporting documentation records). 490-60e <br /> ❑ATG Testing results(and supporting documentation records).490fi8r ❑ Corrosion Protection 60-day logs 490-68,, <br /> ❑Equipment maintenance and calibration records. 490-69h <br /> IX.TRAINING <br /> ®Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to theirjob duties. 490fi9a <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITYD(Check all that apply) <br /> ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)490-69b <br /> ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)490-69c <br /> ® CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 4% 9d <br /> ® CALIFORNIA UNDERGROUND STORAGE TANK LAW 49069. <br /> ® STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"490-69f <br /> ® SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490-69g <br /> ❑ OTHER(Specify):m69h M69i <br /> LJ This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> ➢ The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> ➢ Names of contact person(s)for emergencies and monitoring alarms.490-70 <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.490-71 <br /> M ec-k i ca l F'l ee er 2` /e- <br /> XI.PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that: 1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The following person(s)are responsible for performing the monitoring and equipment maintenance: <br /> NAME Chacko Thomas 490-72 TITLE owner <br /> 490-]3 <br /> NAME Linda Martin 490-74 TITLE Manager <br /> 490-75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XIL OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION: 1 certify that the information provided herein is true and accurate to the best of my knowledge. <br /> APPLICANT GNATURE 490-76 DATE: 490-77 <br /> CcC -v 5/3/2011 <br /> REPM E 1.TeNc eretor 2.F i it Own r for 3.Authari d Re r e t ri (Owner <br /> APPLICANT NAME(print): 490'8 APPLICANT TITLE: 400-79 <br /> Linda Martin Manger <br /> UPCF UST-D(122007)3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.