My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 11:29:01 AM
Creation date
11/2/2018 3:41:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\1405\PR0231485\BILLING 1987-1998.PDF
QuestysFileName
BILLING 1987-1998
QuestysRecordDate
5/11/2018 10:22:36 PM
QuestysRecordID
3890093
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'IIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUNDSTORAGETANK <br /> MONITORING PLAN- Pae 1 of 2) <br /> TYPE OF ACTION ❑1.NEW PLAN [12.CHANGE OF INFORMATION 400-1 <br /> PLAN TYPE 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 4902 <br /> (Check one item only) ❑ 2 THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEMS) <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) _ _ 1 <br /> BUSINESS NAME(Same as FACILITY NAME) IL O C L1��'� L llyN� 3. <br /> BUSINESS SITE ADDRESS Zj0 CJ Q. en <br /> `� <br /> H.EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work most be performed by qualified personnel. <br /> 23 CCR J26322 26342635.2641) <br /> MONITORING EQUIPMENT IS SERVICED Dr I.ANNUALLY490.34 <br /> ❑ 99.OTHER(Specify): 490-36 <br /> III.MONITORING LOCATIONS <br /> I.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. ❑2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 634)490-0 <br /> IV.TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): <br /> 10 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTFFIAL)SPACE(S)OR SECONDARY CONTAINMENT 49x5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> ------ '--- <br /> SECONDARY CONTAINMENT IS: .p,_a.DRY [Ib.LIQUID FILLED ❑ C.PRESSURIZED ❑d.UNDER VACUUM 490'6 <br /> ----------- 4M7 <br /> 49M <br /> '--"---- 49M <br /> PANEL MA_N_UF'ACTURE__ 11 -�M Lr, -_--__ ,t�/;�I{-tr,1... n___ _ <br /> LEAK SENSOR MANUFACTURER. e_Q 0 °90'9 MODEL#(S):'/ I '7 ' I/ 490-16- <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER. 490-12. 490-13 <br /> - MODEL#: <br /> IN-TANK PROBE MANUFACTURER__- _ - _490'14__MODEL#(S): 49015 <br /> ❑ <br /> LEAK TEST FREQUENCY a.CONTINUOUS ❑ b.DAILY/NiGHTLY ❑ c.WEEKLY 400'16 <br /> _ ❑ d.MONTHLY e.OTHER(§pecify):- -49017 <br /> PROGRAMMED TESTS: ❑ a.0.1490-13 <br /> g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): 494-19 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 49azo <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 490-21 <br /> 490.2222 <br /> 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 490v <br /> TEST FREQUENCY. ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 49-24 <br /> 490.25 <br /> [199.OTHER (Specify): 490-26 <br /> 490-27 <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> 1 CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 49-28 <br /> VISUAL ALARMS (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS:❑a.DRY ❑b.LIQUID FILLED ❑c.PRESSURIZED ❑d.UNDER VACUUM 490-29 <br /> PANEL_MANUFACTURER. _ 494-)0 MODEL#: 490-31 <br /> _-_LEAK SENSOR MAN_UFAC_TURER__-_.-___.-____-_- <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(fe,TURBINE)SHUTDOWN. i ❑a.YES ❑b.NO 490-34 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49-35 <br /> 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> -_PRODUCT FLOW WHEN ALEAK IS DETECTED 23 CCR 12636-_-._-____- -- -_ -_ _ --_ 446 <br /> MLLD MANUFACTURER(S): Q Crr _ 49-38E _ - <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490.39 <br /> 49-40 <br /> ELLD MANUFACTURER(S) - _1 MODEL#(S): 490.41----_-- - <br /> PROGRAMMED IN LINE LEAK TEST. ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. 494'42 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES [__1 b.NO 40-43 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 49-44 <br /> 4.PIPE INTEGRITY T S ING 49-45 <br /> TEST PRE UENCY a.ANNUALLY -] b.EVERY 3 YEARS ❑ c.OTHER S(Specify)) 490.46490-47 <br /> ❑ 5.VISUAL PIPE MONITORING. 49-48 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED- 490-49 <br /> •AlbwW for moniro ng ofunbunW em en2y jimernw fuel Pi Ping mly MrHSC 25281.5 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA[23 CCR§2636(x)(3)1. 49o-so <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490-51 <br /> ❑ 99.OTHER(Specify) 490-52 <br /> 490.53 <br /> UPCF UST-D(12/2007)1/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.