My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 11:29:01 AM
Creation date
11/2/2018 3:41:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\1405\PR0231485\BILLING 1987-1998.PDF
QuestysFileName
BILLING 1987-1998
QuestysRecordDate
5/11/2018 10:22:36 PM
QuestysRecordID
3890093
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OIFIED PROGRAM CONSOLIDATED FOR* TANK: TA0506700 <br /> PR#: PRO231485 <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 2 FAC#: FA0000306 <br /> VI.PIPING CONSTRUCTION(Check a0 Wm,Pyly7 <br /> UNDERGROUND PIPING Page 7 on <br /> ABOVEGROUND PIPING <br /> SYSTEM TYPE I.PRESSURE ❑2.SUCTION ❑ 3.GRAVITY 458 ❑ I.PRESSURE ❑2.SUCTION <br /> ❑3.GRAVITY 459 <br /> CONSTRUCTION ❑L SINGLE WALL ❑3.LINED TRENCH ❑99.OTHER 460 ❑ L SINGLE WALL ❑ 95,UNKNOWN <br /> MANUFACTURER <br /> .DOUBLE WALL ❑95. KNO 1 461 ❑2.DOUBLE WALL ❑ 99.OTHER 062 <br /> MANUFACTURER 461 <br /> ❑ 1.BARE STEEL ❑ 6.FRP COMPATIBLE w/mol:METHANOL ❑ 1.BARE STEEL ❑6.FRP COMPATIBLE V 100%METHANOL <br /> ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑ 2.STAINLESS STEEL ❑ 7.GALVANIZED STEEL <br /> ❑PLASTIC COMPATIBLE W/CONTENTS El 95.UNKNOWN ❑PLASTIC COMPATIBLE W/CONTENTS ❑ 95.UNKNOWN <br /> ?!t.4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER ❑4.FIBERGLASS ❑ 8.FLEXIBLE(HDPE) ❑ 99.OTHER <br /> ❑5.STEEL W/COATING ❑ 9,CATHODIC PROTECTION 464 ❑ 5.STEEL W/COATING ❑ 9.CATHODIC PROTECTION <br /> 465 <br /> VII.PIPING LEAK DETECTION(clwx an tht apply)(A d«ription orth moNwri <br /> re pngnttt awn h aubmiac9 to We lural agency.) <br /> INPIPING <br /> SINGLEGLE WALL <br /> PIPING ABOVEGROUND PIPING <br /> PRESSURIZED PIPING(Check all that apply): 466 SINGLE WALL PIPING <br /> PRESSURIZED PIPING(Check all that apply): 467 <br /> ❑ 1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF ❑ I.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF <br /> FOR LEAK SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND <br /> VISUAL ALARMS. VISUAL ALARMS. <br /> [32.MONTHLY 0.2 GPH TEST <br /> ❑3.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 2.MONTHLY 0.2 GPH TEST ❑3,ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑4.DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIEAL PIPING ❑5.DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(No VALUES IN BELOW GROUNDPIPING): ❑6.TRIENNIAL INTEGRITY TEST(0.I GPH) <br /> ❑ 7.SELF MONITORING SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUNDPIPING): <br /> GRAVITY FLOW ❑ 7.SELF MONITORING <br /> ❑ 9.BIENNIAL INTFGRrFY TEST(0.1)GPH GRAVITY FLOW(Check all that apply): <br /> ❑ 8.DAILY VISUAL MONITORING <br /> ❑ 9.BIENNIAL INTEGRITY TEST(0.1)GPH <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) 10.CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(C kone) <br /> �a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑a.AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑6.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑6.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> ❑ C. NO AUTO PUMP SHUT OFF ❑ c.NO AUTO PUMP SHUT OFF <br /> 11.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTION ❑ 11.AUTOMATIC LEAK DETECTOR <br /> 12.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 12.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 13.CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(C6ecka11 Wat apply) EMERGENCY GENERATORS ONLY(Click all Wat apply) <br /> ❑ 14.CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUTOFF• ❑ 14,CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF" <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW ❑ 15.AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW <br /> SHUT OFF OR RESTRICTION SHUT OFF OR RESTRICTION <br /> ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) ❑ 16.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17.DAILY VISUAL CHECK <br /> [:1 17.DAILY VISUAL CHECK <br /> VILL DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT �'7 1,FLOAT MECHANISM THAT SRUTS OFF SHEAR VALVE <br /> DATE INSTALLED /-k E] 4.DAILY VISUAL CHECK <br /> 468 ❑2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS <br /> Q 7 J ❑ 5.TRENCH LINER/MONITORING <br /> o `�1` ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR ❑b.NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE 469 <br /> I mlify not the mf adoa pnvlEel herein is puc atd aowaten th best armykmwkalgc <br /> SIGNATURE OF OWNER/OPERATOR DATE <br /> 490 <br /> NAME OF OWNER/OPERATOR(print) TITLE OF OWNER/OPERATOR <br /> 4]I <br /> n2 <br /> Pnmit Number(Forlwal tacaNYJ 473 P.it A,navvM(For 1.1 me only) 474 <br /> Pmnit Expiration Date(For l«al use only) 475 <br /> PT0000313 EE0000817 6/30/2003 <br /> UPCF(12/99 revised) 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.