My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 11:29:01 AM
Creation date
11/2/2018 3:41:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\1405\PR0231485\BILLING 1987-1998.PDF
QuestysFileName
BILLING 1987-1998
QuestysRecordDate
5/11/2018 10:22:36 PM
QuestysRecordID
3890093
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA +, <br /> STATE WATER RESOURCES CONTROL BOARD �< ° <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B "�� =° <br /> COMPLETE A SEPARATE FORM FOR!A WANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT EK 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSEDN�SITE <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT E] 6 TEMPORARY TANK CLOSURE ED TANK REMOVED /c 1- l <br /> t ' <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: 54- C �p <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.# B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) D. TANK CAPACITY IN GALLONS: <br /> II.TANK 900ENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A [Frl MOTOR VEHICLE FUEL ❑ 4 OIL B. Eo C. ❑ 1# RE"UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ 1 MIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> 1C MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICALPRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.N: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B,AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 UBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM E-] 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESSSTEEL ❑ 3 FIRE SS E] 4 STEEL CLAD Wl FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL F-15 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ ] UMINUM E::] B IW% METHANOL COMPATIBLE W/FRP <br /> (PHm9TY T#Rk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER UNED ❑ 2 ALKYD LINING ❑ 3 OXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS UNING ❑ 6 UNLINED 5all's UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO_ <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 WRAP ❑ d FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION [:j91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,BIC. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE YES_ NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A&1 SINGLE WALL A U 2 DOUBLE WALL A U 3 UNED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE WIFRP <br /> PROTECTION A U 9 GALVANIZED STEEL 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑1 MECNINCAL UN <br /> IE LFN( 2 UNE M NESS 3 CG NUWS INfERSTIfIAI 4 ELECTRCMC LINE 5 AaIATIC PUMP <br /> DETI=A TESTING ❑ WWMING LEAK DETECTCIL ❑ mlf m ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECKMANUAL 2 RECONCILIATIONORV E] 3 VAOZE MONIITORING ❑ 4 AUTOMAXGAUGING MONITORING <br /> TANK ❑ EZ' TAN <br /> 5 MONTORINGTER 8 TESTING <br /> K <br /> ❑ 7 MONITOR U INTERSTITIAL ❑ 8 SIR ❑ 9 TANK LY MANUAL ❑ 10 MOTESTING_HLY TANK ❑ 95 UNKNOWN E]99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATED DATE LAST USED(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES [:j NO❑ <br /> SUBSTANCE REMAINING GALLONS INERTMATERIAL9 <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> (PRINTED 8 SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION It FACILITY# TANK If <br /> STATE I.D.# ff p <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE - j <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APP LI ION-FORM A.UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT WILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THorRGROUND STORAGE TANK REGULATIONS <br /> FORM B (G95) FOR0014B117 <br />
The URL can be used to link to this page
Your browser does not support the video tag.