My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1405
>
2300 - Underground Storage Tank Program
>
PR0231485
>
COMPLIANCE INFO 2001-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/27/2022 11:44:39 AM
Creation date
11/2/2018 3:45:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001-2012
RECORD_ID
PR0231485
PE
2361
FACILITY_ID
FA0000306
FACILITY_NAME
EMILS LIQUOR & SPORTS SHOP*
STREET_NUMBER
1405
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
ESCALON
Zip
95320
APN
22707031
CURRENT_STATUS
01
SITE_LOCATION
1405 CALIFORNIA ST
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CALIFORNIA\1405\PR0231485\COMPLIANCE INFO 2001-2012.PDF
QuestysFileName
COMPLIANCE INFO 2001-2012
QuestysRecordDate
5/14/2018 3:33:43 PM
QuestysRecordID
3891081
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
359
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M M <br /> Vaporless 99 LD-2000 Addendum <br /> 6.0 Test Results and Limitations <br /> The performance parameters for the 99 LD-2000 are summarized in Table 3. <br /> Probability of Detection o) <br /> The 99 LD-2000 was correct in its determination of a leak for all of the leak tests. The estimated <br /> PD of a 3 gal/h leak is 100%with an upper confidence limit of 61 to 100%. <br /> Probability of False Alarm(PFA) <br /> The 99 LD-2000 was correct in its determination of a tight pipeline for all of the right tests. The <br /> estimated PFA is 0%with a lower confidence limit of 0 to 3900. <br /> Time to Conduct a Test <br /> All of the tests were completed in under one minute with one exception. One of the tests required <br /> 20 minutes to complete due to a temperature differential extreme that was present during the test <br /> (See Table 1). <br /> Maximum Line Size <br /> The EPA protocol allows pipeline leak detection methods to be used on pipelines with up to <br /> twice the volume of that used in the evaluation. If the EPA protocol is used to calculate the <br /> performance parameters, the 99 LD-2000 can be used on rigid pipelines up to 170 gallons and <br /> flexible pipelines up to 39.5 gallons. <br /> Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.