Laserfiche WebLink
• SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.ora/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility name: Inspection date: <br /> Emil's Liquor and Sports Shop May 3, 2011 <br /> Facility address: DST#f 1 2 3 <br /> 1405 California Street, Escalon Product 87 91 DSL <br /> Facility contact: Title: Phone: <br /> Chacko Thomas Owner (209) 838-7674 <br /> Monitoring panel: Piping system: Overfill prevention: Violations: <br /> Gilbarco EMC ©pressurized❑sudion❑Grevly ❑XMechanical <br /> ❑Audible/visual ❑Mi-RDeted❑M2-RPrev❑M3-Both <br /> Inspection type: Designated operator. ICC exp.date: <br /> ❑X Routine ❑X Monitoring Certification E]Installation E]Other Karen Arnaiz 6/30/11 <br /> On site Service Technician's name: ICC exp.date: Manufacturees training; <br /> Felix Ramirez 4/11/12 VMI - 11/11/11, VR - 6/28/12 <br /> # Code Section TIONS R <br /> HSC=CA Health&SafetyCode;CCR=CA CodeofRegulations;V=Violation; RV=Repeat Violation V V <br /> 1 HSC 25284 No permit to operate <br /> Secondary containment:(a)test not performed; (e)test report not submitted within 30 days;(f)test <br /> 2 CCR 2637 notification not provided to the Environmental Health Department(EHD)at least 48 hours prior to <br /> conducting the test <br /> 3 CCR 2711 b Current Unified Program Consolidated Forms not on file with the EHD[Facility and tank fore <br /> 4 HSC 25292.2 Current financial responsibility documents not on file with the EHD <br /> 5 CCR 2632(b) Monitoring Program(Monitoring&Response Plans is not current or approved by the EHD <br /> 6 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'% (M1) <br /> years,written performance claims pertaining to release detection systems for 5 years, or records of <br /> repairs, linings, and upgrades for the life of the tank. Monitoring records include:(1)date and time of X <br /> 7 CCR 2712(b) all monitoring or sampling;(2)monitoring equipment calibration and maintenance records;(3)results <br /> of any visual observations;(4)results of sample analysis performed a lab or in the field;(5)logs of all <br /> readings of gauges or other monitoring equipment,ground water elevations,or other test results; (6) <br /> results of inventory readings and reconciliations <br /> 8 CCR 2643(d) Daily monitoring of suction piping(pre-January1, 1984 not performed (Mt <br /> 9 HSC 25292.1 UST system is not operated to prevent unauthorized release, including ills and overfills <br /> 10 CCR 2632(c)(2) Monitoring system is not present in the interstitials ace of a double walled UST (M1) <br /> 11 CCR 2630(d) UST morfitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br /> 12 HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (M1) <br /> containment <br /> 13 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates IM1) <br /> an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 14 CCR 2631 a Prima containment is not product tight <br /> 15 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 16 CCR 2636(c)(1) All releases in secondary pipingdo not flow to a collection sum <br /> 17 CCR 2636(f)(2) Line leak detectors not installed or failed to detect a 3-gallon per hour leak at 10 psi J(mi) <br /> 18 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means <br /> to kee the spill container em <br /> 19 CCR 2635 b 2 Overfill prevention system was overridden or failed to meet overfill requirements in this section <br /> 20 CCR 2636(a) Failed to have seconds containment for piping includes conventional suction piping) <br /> 21 HSC 25291(e) Water in 2°containment not removed,analyzed&property disposed of <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eig22 CCR 2650 hours was not recorded; (e)escaped secondary containment, not cleaned up after eight hours, <br /> sudden loss of product was not reported to the EHD within 24 hours <br /> 23a CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 23b CCR 2715(b) Designated operator did not possess a current ICC UST System Operator certification <br /> EHD inspector: Re cei by: Title: <br /> EHD 23-02-002 REV 08/13110 Page 1 UST INSPECTION REPORT <br />