Y <br /> FiRF Stockton Fire Department• Fire Prevention Division <br /> 345 N. EI Dorado Street, Stockton, CA 95202 CITY OF <br /> (209)937-8271 • Fax(209)937-8893 STOCKTON <br /> DEPT. <br /> Final Approval Requirements <br /> Fire Permit Number: 11/12-371 <br /> Tenant: St. Josephs Hospital <br /> Job Address: 1800 North California Street <br /> Reviewed By: Phil Simon <br /> Date: November 08, 2012 <br /> Proposed Work: Remove existing diesel fuel line on exterior of building. Underground lines will be rinsed, <br /> tested, and filled with concrete slurry for abandonment in place. <br /> COMMENTS - This plan check is not to be construed as an approval for any code items not noted, or commented <br /> on. It is the contractor's responsibility to conform to the provisions of all relevant laws, codes, ordinances, rules and <br /> regulations. Work shall not commence without approved plans unless specifically allowed by the Fire Chief. All <br /> inspections require the"APPROVED"job copy and job card to be available on the job site. <br /> California Fire Code Title 24, Part 9: Matters not provided for. Requirements that are essential for the public <br /> safety of an existing or proposed activity, building or structure, or for the safety of the occupants thereof, which are not <br /> specifically provided for by this code shall be determined by the fire code official. <br /> Inspections — Unless unusual circumstances arise, the developer shall provide at least twenty-four hours notice to <br /> the Fire Department to arrange an inspection. Inspection requests may be made by calling the telephone number <br /> listed above and scheduling either an A.M. inspection (10:00 a.m. to 12:00 p.m.) or a P.M. inspection (1:00 p.m. to <br /> 4:00 p.m.). <br /> Additional Fire Inspection Fee(s) — Additional feels) will be imposed for any additional fire inspections that are <br /> requested. <br /> Additional Fire Department Notes: <br /> 1. Plans Approval —Abandon diesel fuel line due to removal of backup boiler (primary line). Approximately 270 feet <br /> will be abandoned in place and filled with inert solid filling material. Pipes left in place and filled shall have pipes <br /> capped and/or plugged. ALL WORK SHALL BE WITNESSED BY STOCKTON FIRE PREVENTION DIVISION, <br /> FIRE PREVENTION OFFICERS. CONTACT STOCKTON FIRE PREVENTION DIVISION FOR ON SITE FIELD <br /> INSPECTION. <br /> 2. Pipes Abandoned in Place: <br /> 1) Flammable and combustible liquids shall be removed from the existing piping; <br /> 2) Pipes shall be rinsed and tested for combustible vapors: <br /> 3) Pipes shall be filled with concrete slurry: <br /> 4) All open ends of pipes shall be capped or plugged. <br /> 3. Pipes Abandoned in Place—All work shall comply with CFC 3404.2.13.4. <br /> Should you have any questions contact Phil Simon at(209)937-8271. <br /> Final Approval 07/11108 <br />