My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
2300 - Underground Storage Tank Program
>
PR0231532
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/4/2022 2:28:59 PM
Creation date
11/2/2018 3:58:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231532
PE
2351
FACILITY_ID
FA0000185
FACILITY_NAME
CITY FOOD & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
03
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CAMBRIDGE\16470\PR0231532\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
10/23/2012 8:00:00 AM
QuestysRecordID
132740
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
115
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TIED PROGRAM CONSOLIDATED FORM <br /> �./ UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-(Page I of 2) <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION 490 1 <br /> PLAN TYPE ® I.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY 490.3 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S)' <br /> I. FACILITY INFORMATION <br /> FACILITY ID k(Agency Use Only) - - 1 <br /> BUSINESS NAME(Same as FACILITY NAME) Circle K Store #2701205 3 <br /> BUSINESS SITE ADDRESS 16470 Cambridge Streetl0i CI"TY Lathrop 10a <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(eg.,sensors, probes, line leak detectors,etc-) must be performed at the frequency <br /> specified by the equipment manufacturers' instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> (23 CCR 2632.2634.2638.2641 -.__.____. _ ______________________-_AAAA______-____.__. <br /> § � a9o-3. <br /> MONITORING EQUIPMENT IS SERVICED ® 1. ANNUALLY ❑ 99.OTHER(Specify): 49o-36 <br /> III. MONITORING LOCATIONS <br /> S 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN. ❑2.SITE PLOT PLAN/31AP PREVIOUSLY SUBMITTED. (23 CCR 12632, <br /> 2634)49 <br /> IV.TANK MONITORING IS PERFORMED USING THE FOLLOWING'METHOD(S): <br /> ® L CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490-5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632.2634) <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY S b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 49-6 <br /> PANEL MANUFACTURER: Veeder Root 411_ �MODEL 9: TLS-350 410-' <br /> LEAK SENSOR MANUFACTURER: Veeder Root 490-9. I MODEL il(S): 794380-303 440-10 <br /> 2.AUTOMATIC TANK GAUGING(ATC)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 490-1) <br /> PANEL MANUFACTURER: 480-1= MODEL N: 490-D <br /> __----------------- <br /> -______________________ <br /> IN-TANK PROBE MANUFACTURER: .,90,14 MODEL ft(S): 49-19 <br /> --._...__.____-____.____..._.._._...._____...._._....-_.___ <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b. DAILYNIGHTLY ❑ c.WEEKLY 49-16 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490'12 <br /> PROGRAMMED TESTS: ❑ a.0.1 g.p.h. ❑ b.0.2 g.p.h. ❑ c.OTHER(Specify): anis <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 490-20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(NITC)(23 CCR§2645). TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS n 0-22 <br /> i 5.TANK INTEGRITY TESTING(23 CCR§2643.1): 49-23 <br /> TEST FREQUENCY: ❑ a. ANNUALLY ❑ b. BIENNIALLY ❑ c.OTHER(Specify): ew 35 <br /> ❑99.OTHER (Specify): a9Wo-26 <br /> 27 <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) <br /> I.CONI"INUOUS MONITORING OF PIPE/PIPING SUMP(S).AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 490-28 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS: Sa.DRY ❑b.LIQUID FILLED ❑c.PRESSURIZED ❑d. UNDER VACUUM 490'29 <br /> __._..._ _._-______-. <br /> W030 I 490-31 <br /> r PANEL MANUFACTURER: Veeder Root __-_---------------------___ _MODEL pTLS_350 <br /> LEAK SENSOR MANUFACTURER: Veeder Root °90-12 MODEL i#(S): 794380-208 490-'3 <br /> __._.._..____.________--_________ � ________________-__._______-________®_____.___..__________-__. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE SHUTDOWN. a. YES ❑b.NO 4W-34 <br /> FAILUREIDISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. S a.YES ❑b.NO 490-35 <br /> r 2. MECHANICAL LINE LEAK DETECTOR(VILLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED 23 CCR 2636 490-36 <br /> _______S.____- ___�_____________________.__.______ <br /> MLLD MANUFACTURER(S): Red Jacket / FE Petro 490-31 MODEL#(S): FX I V / MLD 490-33 <br /> ❑ 3. ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 49-349 <br /> _._490-41 <br /> ELLD MANUFACfUR_ER(S) __ _ _ _ _ MODEL k(S): <br /> . 4 <br /> PROGRAMMED IN LINE LEAK TEST. ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0 g.p.h 490.42 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a. YES ❑b NO 44041 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES ❑b. NO 49044 <br /> ❑ 4.PIPE INTEGRITY TESTING 49045 <br /> TEST FREQUENCY ❑ a.ANNUALLY ❑ b. EVERY 3 YEARS ❑ c.OTHER(Specify) 49-46490-4r <br /> ❑ 5.VISUAL PIPE MONITORING. 4904x1 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑c MIN MONTHLY&EACH TIME SYSTEM OPERATED' awl-wj <br /> ,Allowfar moniwrtng of wi wto emer eeraur fueli only6 r HSC 15281 5 l <br /> ❑ 6.StCTION PIPING MEETS EXEMPTION CRITERIA 123 CCR§2636(a)(3)1. 490-s0 <br /> ❑ 7 NO REGCLA rED PIPING PER HEAL VH \NI)SAFE"FY CODE,DIVISION 21).CHAP-ER 6.7 IS CONNECTED TO THF:TANK SYSTEM <br /> J9-51 <br /> ❑ 99.OTHER(Specify) 4*ro-s3 <br /> ta'CF t'ST-D(12/2007) <br />
The URL can be used to link to this page
Your browser does not support the video tag.