My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CARNEGIE
>
551
>
2300 - Underground Storage Tank Program
>
PR0503154
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 9:24:57 AM
Creation date
11/2/2018 4:09:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0503154
PE
2332
FACILITY_ID
FA0005704
FACILITY_NAME
SHINKO ELECTRIC AMERICA INC
STREET_NUMBER
551
STREET_NAME
CARNEGIE
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22119064
CURRENT_STATUS
02
SITE_LOCATION
551 CARNEGIE ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CARNEGIE\551\PR0503154\BILLING 1986 - 2012.PDF
QuestysFileName
BILLING 1986 - 2012
QuestysRecordDate
1/4/2018 12:11:23 AM
QuestysRecordID
3760835
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM `B': UNDERGROUND STORAGE TANK PROGRAM <br /> a� �m <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING I ORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: C ..G'1) FARM TANK-YES❑ NO - <br /> I, TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY +� <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: . P � <br /> C. YEAR INSTALLED 0 D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. l--� <br /> A ❑ 1 M,PT6R VEHICLE FUEL ❑ 2 PETROLEUM B. G, ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> Eg-fcHEMICAL PRODUCT ❑ 4 OIL PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOLTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,.ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# K C.A.S.#: <br /> x111. TANK CONSTRUCTION MARK ONE ITEM ONLY96 BOX A,B,1,&D <br /> A.TYPE OF ❑ I DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEELIIRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK <br /> MATERIAL � 5 CONCRETE 5 POLYVINYLCHLORIDE ® 7 ALUMINUM 8 100%METHANOLCOMPATI8LEFRP <br /> ❑ 9 BRONZE © 10 GALVANIZED STEEL ❑95 UNKNOWN OTHEH <br /> C. INTERIOR F-] 1 RUBBER LINED F]2 ALKYD LINING F-13 EPDXY LINING E]4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING [IJA U LINED ❑95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑ YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHLENEWRAP E] 2 TAR OR ASPHALT ❑ 3VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION Z41"NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A 9 OTHER <br /> B. CONSTRUCTION A 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELPRON A U 2 STAINLESSSTEEL A U 3 POLYVINYLCHLORIDE(PVC) A U 4 FIBERGLASSPIPE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD VVI FRP A U 5 10D%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZEDSTEEL A U 95 UNKNOWN A U 99 OTHER <br /> LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S i VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> t� a P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MOIYRI 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? YES [7] NO <br /> GALLONS <br /> THIS FORM HAS 8 N COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> Ell <br /> llar-Ail-7 IT9 FoT�lolcl <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> A) <br /> / PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> J CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> �IIJ1� FORM B I.3-7-68i THIS FORM MUST BE ACCOMPANI eY A FACILITYISITE APPLICATION, FORM 'A',UNLESS ATRARENT FORM`A' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />