My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CARNEGIE
>
551
>
2300 - Underground Storage Tank Program
>
PR0503154
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 9:24:57 AM
Creation date
11/2/2018 4:09:53 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0503154
PE
2332
FACILITY_ID
FA0005704
FACILITY_NAME
SHINKO ELECTRIC AMERICA INC
STREET_NUMBER
551
STREET_NAME
CARNEGIE
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22119064
CURRENT_STATUS
02
SITE_LOCATION
551 CARNEGIE ST
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CARNEGIE\551\PR0503154\BILLING 1986 - 2012.PDF
QuestysFileName
BILLING 1986 - 2012
QuestysRecordDate
1/4/2018 12:11:23 AM
QuestysRecordID
3760835
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM `B': UNDERGROUND STORAGE TANK PROGRAM Fk <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING I ORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT CHANGE OF INFORMATION 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM F-12 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: r_qt% FARM TANK-YES❑ NO - <br /> L TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY C7 <br /> A. OWNERS TANK ID# !� B. MANUFACTURED BY. h <br /> C. YEAR INSTALLEDlclgqD. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> ❑ 3 MICAL PRODUCT ❑ 4 OIL ❑ 1 PROD CT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> 5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN WASTE ❑ 7 METHANOL ff?r9_OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF U+04 M 1433 3l <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# CAS #. +SI Sa��� 13) <br /> xlll. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A. TYPE OF ❑ 1 BLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> F] I STEEL/IRON 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD WIFIBERGLASS REINFORCED PLASTIC <br /> MATERIAL <br /> B.TANK 5 CONCRETE 6 POLYVINYL CHLORIDE 7 ALUMINUM 6 100% OL COMPATI8LE FRP <br /> ❑ 9 BRONZE E:] 10 GALVANIZED STEEL ❑ 95 UNKNOWN OTHER <br /> ❑ <br /> C. INTERIOR 1 RUBBER LINED ❑ 2 AL LINING El 3 EPDXY LINING 4 PHENOLIC LINING <br /> LINING ❑ 5 GLASS LINING EglrUNLINED ❑ 95 UNKNOWN <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TMi4ASPHALT ❑3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION I NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U dF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A 099 OTHER <br /> B. CONSTRUCTION A SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/ERR A U 6 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE Cl <br /> P S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURETESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST U5€0(MO/YR) 2. ESTIMATED QUANTITY pF GALLONS 3. WAS TANK FILLED WITH <br /> LSUBSTANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> �JJ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED$.SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TAANK ID# <br /> CURRENT LOCA' GEY FACILITY #� APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY; <br /> l! <br /> FORM B(3-7-88) THIS FORM MUST BE ACCOMPANIOW A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A w RENT FORM`A" HAS BEEN FILED <br /> DATA PROCESSING COPY <br />