My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CARPENTER
>
3480
>
2300 - Underground Storage Tank Program
>
PR0231533
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/15/2021 11:50:59 PM
Creation date
11/2/2018 4:13:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231533
PE
2381
FACILITY_ID
FA0003745
FACILITY_NAME
ROTO ROOTER
STREET_NUMBER
3480
Direction
E
STREET_NAME
CARPENTER
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
17916040
CURRENT_STATUS
02
SITE_LOCATION
3480 E CARPENTER RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CARPENTER\3480\PR0231533\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
2/28/2012 8:00:00 AM
QuestysRecordID
133869
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD • <br /> FORM `B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> .gym <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. - Z <br /> 10 <br /> MARK ONLY ❑ 1 NEWPERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED 5 <br /> W <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: W r. ^ N 96 6 FARM TANK-YES NO DO <br /> lU <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY W <br /> A. OWNERS TANK IDN ol I B. MANUFACTURED BY: U -O <br /> C. YEAR INSTALLED 1(tal I D. TANK CAPACITY IN GALLONS: l `00 <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. Ml MOTOR VEHICLE FUEL ❑2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL z 1 PRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ 80 EMPTY C-]95 UNKNOWN ❑2 WASTE ❑7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.R C.A.S.R: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A. TYPE OF 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑ 4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEELPRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL GAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑ B 1OD%METHANOL COMPATIBLE FRP <br /> ❑ 9 BRONI&' ❑10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> F-11 RUBBER LINED ❑2 ALKYD LINING ❑3 EPDXY UNING ❑d,KENOUC UNING <br /> C.INTERIOR 5 GLASS LINING 6 UNLINED 95 UNKNOWN <br /> LINING ❑ <br /> ❑ IB UNING MATERAL COMPATIBL 0096 METHANOL? ❑YES ❑ NO �90THER I/�/"' — <br /> D. CORROSION ❑ 1 POLYETHLENEWRAP EK2 TAR OR ASPHALT ❑3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A& <br /> 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A_U 91 NONE AU 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A 195 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK 0 8 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P 8 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(Mf/YR 2. ESTIMATED QUANTITY OF U1GALLONS3.WAS TANK FILLED WITH <br /> 'AV/ SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION k AGENCY k FACILITY ID R TANK ID M <br /> 3I Od I I I -ED = 1610111 <br /> CURRENT LOCAL AGENCY FACILITY ID p APPROVED BY NAME PHONE N WITH AREA CODE <br /> gor&3 " `/ i2 ' <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK N PERMIT AMOUNT I SURCHARGE AMT. FEE CODE <br /> 0"EIPT N BY: <br /> FORM E(6 29-88) THIS FORM MUST BE ACCOMPANIED BY AFACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS SEEN FILED <br /> DATA PROCESSING COPY <br />