BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHANNEL
>
1630
>
2300 - Underground Storage Tank Program
>
PR0502961
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2021 11:19:46 PM
Creation date
11/2/2018 4:28:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0502961
PE
2381
FACILITY_ID
FA0005631
FACILITY_NAME
SJ CHERRY GROWERS
STREET_NUMBER
1630
Direction
E
STREET_NAME
CHANNEL
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
15304021
CURRENT_STATUS
02
SITE_LOCATION
1630 E CHANNEL ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHANNEL\1630\PR0502961\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
3/9/2012 8:00:00 AM
QuestysRecordID
135175
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION m <br /> COMPLETE_.A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. — Z <br /> _ 10 <br /> MARK ONLY ❑ 1 NEWP.ERMIT ❑3 RENEWALPERMIT ❑6 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑4 AMENDEDPERMIT ❑6 TEMPORARY TANK CLOSURE t5ZLe TANK REMOVED El <br /> ^' N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: so raw FARM TANK-YES❑ NOCE�:[ 41b <br /> w <br /> I. TANKDESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY N <br /> A. OWNERS TANK IDR B. MANUFACTURED BY: t4v N w <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: SS(D <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. CSV_MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑4 OIYT ($1 PRODUCT ❑4 GASAHOL ❑5 JET FUEL E:]6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑80 EMPTY [:]95 UNKNOWN ❑2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.R C.A.S.R: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,AD <br /> A.TYPE OF 1 OOUBIEWALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLEWALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> STEELPRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL GLAD WIFIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑B 1 D METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑ 99 OTHER <br /> C. INTERIOR r_1i RUBBER LINED E]2 ALKYD LINING ❑ 3 EPDXY UNING ❑ 4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑fi UNLINED EaK UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH ID0%METHANOL? ❑YES ❑NO J OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP ❑ 2TAR OR ASPHALT ❑3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION [�K 91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE xt7l SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE 95 UNKNOWN A U 99 OTHER <br /> A U1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A 05 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S i VISUAL CHECK S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P 8 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED A SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY R JURISDICTION R AGENCY R FACILITY ID K TANK ID R <br /> CURRENT LOGALn) o AGED NCY FACrILITY ID R APPROVED BY NAME PHONE R WITH AREA CODE <br /> + c !/ <br /> PERMIT NUMBER PERMIT APPRO AL DATE PERMIT EXPIRATION DATE <br /> N <br /> CHECK PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT R BY: <br /> FORM B(6-29-BB) THIS FORM MUST BE A9.%;OMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.