Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.s coq v.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VANCO TRUCK-AUTO PLAZA 1 1033 W CHARTER WAY STOCKTON June 22 2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status c V R COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status e V e R c COS <br /> 324 CCR 2717.1(g) Tampered with red tag c V e R n COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST c V c R c COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms c V e R e COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored e V e R c COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements In V ❑R ❑COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements e V E R e COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system In V e R e COS <br /> Single-Walled Non-Pressurized R <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V ❑R c COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) in V In R COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) -V -R COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation V _. R _COS <br /> 2030 See below Unlisted Operations/Maintenance violation DV ❑R u COS <br /> 2060 See below Unlisted Design/Construction violation DV UR -COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator at the time of inspection. The EHD will generate and <br /> provide a complete report to the facility operator. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING THIS <br /> FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date�:% vv /I I Inspector: Inspector Phone: <br /> Printed Name and Title: ELEN , Lead Senior RENS (209) 953-7699 <br /> FA0003829 PR0232352 SC001 06/22/2017 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 3 Underground Storage Tank Program OIR <br />