My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> �� <br /> Environmental Health Department FILE <br /> 1868 East Hazelton Avenue, Stockton; California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web;www.sjgov.orcyehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> VANCO TRUCK-AUTO PLAZA (209)466-0833 June 22, 2017 <br /> Facility Address: CERS ID: <br /> 1033 W CHARTER WAY, STOCKTON, CA 95206 10181461 <br /> Inspection Contact: Title: Phone: <br /> Mike Boparai Owner (209)466-0833 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361- UST FACILITY <br /> Consent For: I Consent Given By: <br /> x Inspection X Photos 0 Sam les I Mike Boparai, Owner <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Fred Babel 03/16/2019 Chris Adams 02/09/2019 <br /> Service Technician Manufacturer's Training <br /> VR, 1104/18, VMI, 10/07/17 <br /> California o e of ReguTafions HSC-Heath and Safety Code CFR=Code of FederalRegulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate ■V ❑R :-.COS <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system u V ❑R COS <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted ■V c R ■COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ❑V ❑R COS <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan s V ❑R ■COS <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan ❑V ❑R COS <br /> 107 CCR 2632(4)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V ❑R ■COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing e V _ R ❑COS <br /> 109 CCR 2637 Failed to test secondary containment ■V ❑R ❑COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days r V ❑R ❑COS <br /> 111 CCR 2638(.) Failed to test monitoring and leak detection equipment annually ❑V ❑R ❑COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ❑V ❑R ❑COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days ❑V ❑R ❑COS <br /> 114 CCR 2636(1) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V o R o COS <br /> 115 CCR 2715(x) Failed to inform the EHD of designated operator identification or change within 30 days ❑V D R ❑COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V ❑R ❑COS <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after ❑V ❑R ❑COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V :- R ❑COS <br /> 119 HSC 25299 Documents were falsified or misrepresented ❑V ❑R ❑COS <br /> 120 CCR 2635(d) Failed to submit UST Certification of InstallationlModification ❑V u R o COS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V D R o COS <br /> 612�2CCR 2631 Q) Failure to submit UST system component statement of compatibility for substance stored ❑V ❑R ❑COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions ❑V ❑R ❑COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 112 years ❑V n R n COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site ❑V ❑R ❑COS <br /> FA0003829 PR0232352 SC001 06/22/2017 <br /> EHD 23-01 Rev.09122/16 Page 1 of 6 Underground Storage Tank Program OIR <br /> 91719690 0935 0131 4339 41 <br />
The URL can be used to link to this page
Your browser does not support the video tag.