My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1313
>
2300 - Underground Storage Tank Program
>
PR0231049
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/16/2021 12:03:21 AM
Creation date
11/2/2018 4:39:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231049
PE
2381
FACILITY_ID
FA0003765
FACILITY_NAME
AIRPORT SHELL*
STREET_NUMBER
1313
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15137007
CURRENT_STATUS
02
SITE_LOCATION
1313 E CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1313\PR0231049\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/9/2014 6:00:58 PM
QuestysRecordID
116724
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. " <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE a TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: AiRpou S <br /> ffEu- <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN LL <br /> A OWNERS TANK I.D.R 7 O - B. MANUFACTURED BY: FEEL: <br /> C. DATE INSTALLED(MMAYNEAR) 1273 D. TANK CAPACITY IN GALLONS: 104 tgoo <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A I IN 1 MOTOR VEHICLE FUEL ❑ d OIL B. C. 1a RCGUTAP UMFADm ❑ 3 DIESEL ❑ 8 AVIATION GAS <br /> F2 PETROLEUM ❑ BO EMPTY 1 PRODUCT tb P .= <br /> REMM WLEADm ❑ 0 GASAHOL ❑ 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ to MDGRADE UNLEADEDO 5 JET FUEL ❑ 8 M85 <br /> ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM 0.BELOM <br /> D. IF(Al)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A S R <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF y❑I-'�yy 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> E <br /> SYSTEM X 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ d STEEL CLAD WI FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE WIFRP <br /> "mMy TNI) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED �❑ 2 ALKYO LINING ❑ 3 EPDXY LINING ❑ d PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING //�I 6 UNLINED ❑ 95 UNKNOWN E:] 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES— NO_ <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ d FIBERGLASS REINFORCED PLASTIC <br /> CORROSION I <br /> PROTECTION ❑ 5 CATHODIC PROTECTION M91 NONE F-1 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,BLC. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE YES_ NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND,BOTH IFAPPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A V2 PRESSURE A U 3 GRAVITY A U d FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A g)1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A v i BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U d FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE WIFRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑t v:nubw ux6 IFAX ❑2 MiE TDI M ❑3 mm9Nau3 NTEAm9u ❑d pE0 tc u9L (]5 Awro m wW <br /> OEIECT011 TES1Rq 4 Twm f21dt OETECmR SNUI9ONN ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 MANUAL INVENTORY <br /> IATION ❑ 3 VADOMONITORING ❑ d AUTOMATIC TANK ❑5 GGRROUND GTER ❑6 TESTING❑ 7 MONITORING <br /> INTERSTITIAL ❑ 6 SIR ❑ 9 TANKER ANOA ❑10 MONTHLY TANK a 95 UNKNOWN ❑99 OTHER <br /> STIN <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DATE LAST USED(MOIDAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL T <br /> THIS FORM HAS BEEN C PLETED DER PENAOF RJURY;AN TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANK OWNEWA S NAM / pg7E <br /> (AHK 656NATA <br /> y <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED 0 E FOUR Nu'WaS BELOW <br /> COUNTY L JURISDICTION R FACILITY A TANK L <br /> STATE I.D.# m <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORMA,UNLESS A CURRENT FORMA HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALIATONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLAN. RLE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORM B (695) <br />
The URL can be used to link to this page
Your browser does not support the video tag.