BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
441
>
2300 - Underground Storage Tank Program
>
PR0231056
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 3:06:29 PM
Creation date
11/2/2018 4:48:11 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231056
PE
2381
FACILITY_ID
FA0003628
FACILITY_NAME
ARCO STATION #2168*
STREET_NUMBER
441
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
14707607
CURRENT_STATUS
02
SITE_LOCATION
441 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\441\PR0231056\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
3/9/2012 8:00:00 AM
QuestysRecordID
114394
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORN WATER RESOURCES CONTR,' <br /> FORM 'B': UNDRGROUND STORAGE TANK PROGRAM (az <br /> TANK TANK PERMIT APPLICATION INFORMATION COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY F-] 1 NEW PERMIT ❑3 RENEWAL PERMIT P6f5 CHANGE OF INFORMATION ❑ 7 PFAANENTLY CLOSED TANK CO <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE TANK REMOVED '9 SNev <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: S� FARM TANK-YES❑ NO O'I <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY gf lU ~ <br /> tJ1 <br /> A. OWNERSTANKIDpjw -5B. MANUFACTURED BY: k N <br /> C. YEAR IN STALLED [- D. TANK CAPACITY IN GALLONS: 3 � <br /> II. TANK CONTENTS IF(A1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑2 ROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED ❑3 DIESEL <br /> F-13 CHEMICAL PRODUCT 4 OIL ❑ 1 PRODUCT ❑4 GASAHOL ❑ 5,4F FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN Yal"WASTE ❑7 METHANOL Z99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF _ <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: /p?U 3,J <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,8 D <br /> A. TYPE OF ❑ DOUBLE WAUED F-13 SINGLE WALLED WITH EXTERIOR UNER ❑95 UNKNOWN <br /> SYSTEM SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> 1 STEEL/IRON ❑2 STAINLESS STEEL F-1 3 FIBERGLASS ❑ 4STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑ <br /> MATERIAL 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑B 1D METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR F-11 RUBBER LINED ❑2 ALKYD LINING ❑3 EPDXY LINING ❑ ENOLIC LINING { <br /> LINING F-15 GLASS LINING ❑6 UNLINED 95 UNKNOWN <br /> ❑ IS UNING MATERIAL COMPATIBLE WITH 100%MEfHANOL9 ❑YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TARORASPHALT ❑3 LWAAP F-]4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDE OUNO,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A 5 UNKNOWN A U 99 OTHER <br /> A U i STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUMA 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 5 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 1K <br /> I" P 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION • S 3 VADOSE WELLS P B 4 ELECTRONIC MONITOR P S 5 GROUNDWATER MONITORING WELLS <br /> P 6 PRECISION TESTING P 5 7 PRESSURE TESTING P 8 91 NONE P B 95 UNKNOWN P 8 99 OTHER <br /> VI.49FORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE.IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED 6 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION R AGENCY# FACILITY ID# TANK ID# <br /> DO 10 S D v a5 <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> S <br /> PERMIT NUMBER PERMIT PPROIUIL/6/DA PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. rJNJ(// FEE CODE VECEIPT# BY: <br /> FORMB(6-29-88) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM `A',UNLESS A CURRENT FORMA' HASBEENFILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.