Laserfiche WebLink
v <br /> STATE OF CALIFORNIA 1 <br /> STATE WATER RESOURCES CONTROL BOARD �` •• <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION- FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. `"'•�• <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION VW7 PERMANENTLY CL SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ a AMENDED PERMIT ❑ 5 TEMPORARY TANK CLOSURE 9 TANK REMOVE <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: AKM 2Xb 41 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.0.9 2 8. MANUFACTURED BY: l).AI 1. <br /> C. GATE INSTALLED(MQOAYHEAR) ',O D. TANK CAPACITY IN GALLONS: lv r` <br /> IL TANK CONTENTS IF Al IS MARKED.COMPLETE ITEM C. V <br /> A. t MOTOR VEHICLE FUEL ❑ a OIL 8. D ❑ I9IRN REGULAR 06 <br /> 3 DIESEL ❑ 8 AVIATKNI GAS <br /> ❑ 2 PETROLEUM ❑ SO EMPTY �1 PRODUCT 19PREMUM a GASA'OL 7 METHANOL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2UNL DD ® 5 JET FUEL ❑ <br /> W OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED l9 L C.A.S.9 <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.8.AND C.AND ALL THAT APPLIES IN BOX D AND <br /> A TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ s SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> B. TANK ® I RARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ a STEEL CUA W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ e POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ S 1DD% METHANOL COMPATIBLE W/FRP <br /> (Pdmmy Twk) ❑ 9 BRONZE ❑ 10 GALVAN12ED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ a PHENOLIC LNNG <br /> C INTERIOR <br /> ❑ S GLASS LINING 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL 7 YES_ NO— <br /> D.CORROSION ❑ I POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP ❑ a FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 95 UNKNOWN ❑ n OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED MAR) <br /> IV.PIPING INFORMATION CIRCLE AIFASOVEGROUNDORUIFUNOERGROUNO.BOTHIFAPPLCABLE <br /> A. SYSTEM TYPE A U 1 SUCTION AU2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 90 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)AU FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U S CONCRETE A U 7 STEEL V COATING <br /> A U S 100% METRANOL COMPATIBLE WrFRP <br /> PROTECTION A U 9 GALVANREO STEEL A U 10 CATHODIC PROTECTION A D 95 UNKNOWN A U ao OTHER <br /> D. LEAK DETECTION IeCri AUTOMATIC LINE LEAK DETECTOR gr2 LINE TIGHTNESS TESTING ❑ O MONITORING 7199 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑IV1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING ❑ a AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> IV <br /> 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATEP DATE,L,AST USED q 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH Y <br /> 'Z 7 6 SUBSTANCE REMAINING GALLONS INERT MATERIAL? E= No <br /> THIS FOWHAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME <br /> (PRIxTED a slcxAnnn DATE Z+ <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS SOMPOISED OF THE F04R NUM RS BELOW <br /> COUNTY 9 JURISDICTION/ FA 9 TANK N / <br /> STATE LD.# 2 61 D <br /> PERMITNUMBER PLERMIT APPROVED BYiID E PERMIT EXPIRATION DAT <br /> Zl9 <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS B <br /> FORMS (1291) I'" FI <br /> FILE THIS FORM WITH THE LOI.AGENCY IMPLEMENTING THE UNDERGROUND STORAGE"NK REGULA NS <br /> �, FCN00115G9 <br />