,NYIMUM VERIFICATION LABORATORY ANALYSIS <br /> TANK TANK TPH-G TPH-D BTX &-E CL HC TOTAL MTBE METALS PCB <br /> x CONTENTS 8015 8015 8020 8010 LEAD TBA, ICRP/ 8270 <br /> 8260 8260 8260 8240 7420 DIPS, AES or 8080 <br /> 7421 ETBE, AA <br /> TAME <br /> 8260 <br /> I—II LEADED GAS i X X X X <br /> UNL GAS X X X <br /> DIESEL X X <br /> KEROSENE X X <br /> UNK FUEL X X X X X <br /> PROD. OIL X X <br /> CHLOR. <br /> SOLVENTS X X <br /> i <br /> NONCHLOR <br /> SOLVENTS X X X <br /> WASTE\ <br /> 5 USED OIL X X X I X X X <br /> All analysis methods are the designated EPA methods described in EPA SW 846, Third Edition. Those methods not found in <br /> SW 846 are specifically noted below. Refer to the "SWRCB LUFI' Field Manual", Appendix D (B), Table 3-5 on page A20 for <br /> minimum detection limits for motor vehicle fuel(gasoline and diesel). Refer to 1-2-3 "Regional Board Staff Recommendations <br /> for Initial Evaluation and Investigation of UST's" for the waste and motor oil minimum detection limits. <br /> Detection Limits that remain below the MCL, STLC or Allowable Limit of the contaminant in question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSES TERMINOLOGY: <br /> TPH-G Total Petroleum Hydrocarbon,Gasoline. GC/FID(5030)8015 mod or GC/MS 8260 <br /> TPH-D Total Petroleum Hydrocarbon, Diesel. GC/FW(3550), 8015 mod or GCIMS 8260 <br /> BTX&E - Benzene,Toluene, Xylene&Ethyl Benzene,GC/PID WW or GC/MS 8260 <br /> CL HC Chlorinated Hydrocarbon. GC/HSD 8010,GC/MS 8240 <br /> TOTAL LEAD Total lead, AA 7420, AA 7421 or ICP-AES 6010 <br /> MTBE,TAME,DIPE.TBA GC/MS 8260 <br /> METALS ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption Spectrometry 7000. <br /> Metals:Cadmium,Chromium III and VI,Lead, Zinc and Nickel. <br /> PCB Polychlorinated Biphetryls, GC/MS 8270 or 8080 <br /> GC-FID Gas Chromatography, Flame Ionisation Detection <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation, extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive detection of benzene,benzene-free solvents are to be used. Fused capillary columns are preferred to packed <br /> columns: a packed column may be used as a"first cut' with "dirry" samples or once the hydrocarbons have been characterized and proper <br /> QA/QC is followed. <br /> For drinking water sources, EPA recommends that the 500 series for volatile organic should be used in preference to the 600 series because the <br /> detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal comamination may require further analysis. <br /> PHS-EHD recommends holding those samples until disposal is indicated. <br /> EH 23 046 (Revised 10/19/98) Page 8 <br />