M' 413M VERIFICATION LABORATORY A' %YSIS <br /> TANK TANK TPN-O TP11-D BTX dr E CL HC TOTAL EDB METALS PCB <br /> # CONTENTS 8015 8015 8020 8010 LEAD ICAP/ 8270 <br /> 8260 8260 8260 8240 7420 8240 AES or 8080 <br /> 7421 AA <br /> A <br /> X X X X <br /> X X <br /> X X <br /> KEROSENE X X <br /> UNK FUEL X X X X X <br /> PROD. OIL X X <br /> CHLOR. <br /> SOLVENTS X X <br /> NONCHLOR <br /> SOLVENTS X X X <br /> =OIL OIL X X X X X X <br /> All analyses methods are designated EPA methods described In EPA SW 846, Third Edition. Those methods not found <br /> in SW 846, are specifically noted below. Refer to the "SWRCB LUFF Field Manuai", Appendix A-20, Table 3-5 for <br /> detection limits of motor vehicle fuels (gasoline and diesel). Refer to 1-2-3 "Regional Board Staff Recommendations for <br /> Initial Evaluation and Investigation of USTs' for the waste and motor oil detection limits. <br /> Detection Limits that remain below the MCI, STLC or Allowable Limit of the contaminant In question will be accepted, <br /> however laboratory shall utilize the most conservative method. <br /> LABORATORY ANALYSFS TERMINOLOGY: <br /> TNI-0 Total Petroleum Ilydrocarbon, Gasoline, OpFID (5030) 8015 mod or GC/MS 8260 <br /> TPII-D Total Petroleum Hydrocarbon, Diesel, GC/FID (3550), 8015 mod or GC/MS 8260 <br /> BTX dr E Benzene, Toluene, Xylene h Ethyl Benzene, OCRID 8020 of OCIMS 8260 <br /> CL HC Chlorinated Hydrocarbon, OCAISD 8010, OC/MS 8240 <br /> TOTAL LEAD Total lead, AA 7420, AA 7421 or ICP-AFS 6010 <br /> EDB Ethylene dibromide (DI IS-AB 1803), OC/MS 8240 (DI IS-LUFL) <br /> OC-FID Gas Chromatography, Flame Ionization Defection <br /> ICAP or AA Inductively Coupled Plasma Atomic Emission Spectrometry 6010 or Atomic Absorption <br /> Spectrometry 7000. Metals: Cadmium, Chromium 111 and VI, Lead, Zinc and Nickel. <br /> PCD Polychlorinated Blphenyls, GC/MS 8270 or 8080 <br /> Method 3050 Acid digestion <br /> Method 3540 Soxhlet sample preparation <br /> Method 3550 Sonication sample preparation, extraction method <br /> Method 5030 Purge and trap sample preparation <br /> QA/QC Quality Assurance/Quality Control <br /> Notes: To avoid false positive defection of benzene, benzene-free solvents are to be used. Fused capillary columns are <br /> preferred to packed columns; a packed column may be used as a 'first cut' with 'dirty" samples or once life hydrocarbons <br /> have been characterized and proper QA/AC is followed. <br /> For Drinking water sources, EPA recommends that the 500 series for volatile organics be used in preference to the 600 <br /> series because the detection limits are lower and the QA/QC is better. Samples exhibiting any level of heavy metal <br /> contamination may require further analysis. PIIS-EIiD recommends holding these samples until disposal Is Indicated. <br /> Ell 23 048 (Revised 7/10/92) Page 8 <br />