Laserfiche WebLink
1' <br />SAN lOAOUIN <br />CdblIffY PUBLIC HEALTH SERVICES/ENVIRONMENTAL HEALI�DIVISION <br />No <br />Permit X <br />UGST WORKSHEET FOR SITE CLOSURE EVALUATION <br />DATE <br />tea_ <br />HANE OF FACILITY <br />Code <br />Average Annual Precipitation <br />S <br />SWEEPS CODE <br />ADDRESS <br />Yes <br />No <br />C c.�9,� <br />v v r� <br />TANK ID X <br />O SCJ D_3 <br />TANK SIZE D <br />FUEL TYPE �' <br />Age of Tanks(if available) <br />II. GENERAL SIT HISTORY <br />of Tank <br />Steel <br />Na <br />Is permit current? <br />Yes <br />NO <br />No <br />Permit X <br />- <br />Facility <br />Status <br />Code <br />Average Annual Precipitation <br />If yes, give date(s) <br />Ooc.Soil/GW Cant <br />.+r <br />Yes <br />Yes <br />No <br />No <br />Number of Tanks at <br />facility <br />Was repair done under inspection? Yes <br />Age of Tanks(if available) <br />Type <br />of Tank <br />Steel <br />Na <br />Fbrgl <br />BTXE <br />Sngl <br />Dual <br />ft; ft; ft <br />III. TANK HISTORY <br />V. Site Feature - Leaching Potential Analysis <br />catastrophic <br />long-term leakage <br />overfill <br />Was Tank tested? <br />Yes <br />NO <br />No <br />YESNO <br />Failed precision test ?IYes <br />F <br />No <br />Average Annual Precipitation <br />If yes, give date(s) <br />14 <br />Was a repair made to the tank system? <br />Yes <br />No <br />No <br />If yes, what was repaired? <br />Was repair done under inspection? Yes <br />No <br />Were soil samples analyzed? <br />Yes <br />Score5 <br />10 pts <br />if <br />condition <br />is met <br />Na <br />Score <br />9 pts <br />if <br />condition <br />is met <br />BTXE <br />Score <br />5 pts <br />if <br />condition <br />is met <br />TPH-G TPH-01 Pb/ED8 <br />ft; ft; ft <br />Type of failure/discharge <br />V. Site Feature - Leaching Potential Analysis <br />catastrophic <br />long-term leakage <br />overfill <br />51-100 <br />unknown <br />25-50\1 <br />other: <br />IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br />Soil Samples Received I Yes <br />YES <br />NO <br />No <br />YESNO <br />Depth to Ground Water <br />Ref/Year <br />DATE REFERRED <br />Average Annual Precipitation <br />A= <br />14 <br />10-25 <br />On -Site Wells) Yes <br />No <br />Number & Type <br />Irr <br />Dam <br />Pub <br />S <br />C <br />0 <br />R <br />E <br />Score5 <br />10 pts <br />if <br />condition <br />is met <br />C <br />0 <br />R <br />E <br />Score <br />9 pts <br />if <br />condition <br />is met <br />S <br />C <br />0 <br />R <br />E <br />Score <br />5 pts <br />if <br />condition <br />is met <br />Distance to Wells) from Tank <br />ft; ft; ft <br />V. Site Feature - Leaching Potential Analysis <br />Minimum Depth to groundwater from the Soil Sample (feet) <br />>100 <br />51-100 <br />I <br />25-50\1 <br />Fractures in subsurface (applies to foothills or mountain areas) <br />None <br />( Unknown <br />Present <br />Average Annual Precipitation (inches) <br />xxxxxxl <br /><10 <br />9 <br />110-25 <br />xxxxxxx <br />26-40\2 <br />Man -Made conduits which increase vertical migration <br />of leachate (i.e., septic systems, water wells, ponds) <br />None <br />I Unknown <br />Present <br />Unique site features: Recharge area, coarse soil, nearby wells. <br />xxxxxx <br />None <br />At least <br />one <br />More than <br />one <br />COLUMN TOTALS»>TOTAL POINTS <br />* <br />_ <br />Sample Result: (B T X OR E) <br />RANGE OF TOTAL POINTS <br />49 pts or more <br />41 - 48 pts <br />40 pts or less <br />MAXIMUM ALLOWABLE B -T -X -E LEVELS (PPM) <br />B <br />1 <br />T <br />50 <br />X <br />50 <br />E <br />50 <br />B T X <br />.3 .3 1. <br />E <br />1. <br />NA\3 <br />Sample Result: <br />TPN <br />GASOLINE <br />MAXIMUM ALLOWABLE TPH LEVELS (PPM) <br />DIESEL <br />1000 <br />100 <br />10 <br />10,000 <br />1000 <br />100 <br />FOOTNOTES: --If documented soil and/or ground water contamination is present, do not complete the Leaching potential <br />analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br />\1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br />\2 If precipitation is > 40 inches, score 0 points. <br />\3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br />VI. STAFF RECOMMENDATION/CONCLUSION <br />1. Are BTX & E or TPH Concentrations > Allowable Levels -Yes INOT7 <br />2. Recommend Site Closure Yes No `If Yes, Refer to Site Mitigation for Evaluation <br />VII. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br />CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE <br />YES <br />NO <br />REFERRED TO SITE MITIGATION FOR EVALUATION <br />YESNO <br />DATE REFERRED <br />/ / <br />DATE CLOSURE LETTER MAILED <br />/ / <br />NAME OF <br />EVALUATOR <br />EH 23 80 (UGTWKSHT)\5/90 <br />