San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sogov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RANCHO SAN MIGUEL MARKET* 612 S Cherokee Ln, Lodi October 25, 2016 <br /> UST System Observations <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status n V o R o COS <br /> 324 CCR 2717.1(g) Tampered with red tag n V o R n COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST c V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V n R n COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements a V n R in COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements n V a R in COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system 7 V n R COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V R 7 COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V o R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V c R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V u R n COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation o V o R o COS <br /> 2030 See below Unlisted Operations/Maintenance violation o V o R o COS <br /> 2060 See below Unlisted Design/Construction violation OV o R �COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the 87 and 91 tanks are not current in CERS. The overfill prevention section of <br /> each tank is listed as ball float however, the monitoring plans for each tank have audible visual alarms listed at 90% <br /> overfill prevention. Any change of information must be updated in CERS within 30 days of the changes. <br /> Immediately log into CERS, update the required information, and submit for review by the EHD. The Compliance <br /> Manager Jesus Jurado changed overfill to Fill Tube Shut-Off Valves for both tanks and removed the comments for <br /> audible visual alarms at 90% overfill prevention in the monitoring plan. This was corrected on site. <br /> This is a repeat violation, Class II. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and note the correct test dates for the secondary containment test on the <br /> October 2016 designated operator monthly inspection report. The test date listed is 9-26-16, the correct test date on <br /> file is 8-26-16. During the monthly inspection, the designated operator shall check that all required testing and <br /> maintenance for the UST system have been completed and document the dates they were done. Ensure that <br /> designated operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> FA0014852 PRO521866 SC001 10/25/2016 <br /> EHD 23-01 Rev.09/22/16 Page 3 of 4 Underground Storage Tank Program DIR <br />