My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
800
>
2300 - Underground Storage Tank Program
>
PR0231325
>
COMPLIANCE INFO 2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2022 1:47:12 PM
Creation date
11/2/2018 5:16:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0231325
PE
2361
FACILITY_ID
FA0003997
FACILITY_NAME
PLAZA LIQUOR #1
STREET_NUMBER
800
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742004
CURRENT_STATUS
01
SITE_LOCATION
800 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\800\PR0231325\COMPLIANCE INFO 2009 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
3/28/2017 7:00:00 PM
QuestysRecordID
3360547
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
03/26/2010 02: 15 12093697888 ❑IT LODI AUTO/OASIS PAGE 05 <br /> I <br /> I <br /> I <br /> D Results of Testing/Servicing <br /> Software version Installed: 1b 04 i <br /> Com Iste the following checklist! <br /> 'fes G NoIs the audible claret p6rational7 <br /> ® Yps { No" is the visual alarm n erstional? <br /> © Yes L] No" Were all sensors vis ally inspected,functionally tested,ani confirmed operational? _ <br /> ® Yezi E] Nc' Were all sensors in tallad at lowest point of secondary containment and positioned so that of r equipment will not interfere with their proper <br /> operation? <br /> ❑ Yea Q No' If alarms are rolayeo to s remote mofittoring station,is ail communications equlprnent(e.g.,mm to)operational'] <br /> Nis <br /> ® Yes C7 No" For pressurized piping systems•does the turbine automatically shut down if the piping SeWnE]a containment monitoring system detects B leak, <br /> C1 N/A Tails to operate.or s electrically disconnected? If yes: which sensors initiate positive shut, '.vn7 (check a1l that apply) ( Sumprrre,ch <br /> Sensors; ®Dlspersercontainmenl Sensors. <br /> Did you confirm poa tive Shut-down due to leaks stn ,sensor failuremisoonnactioril 19 Yea; ❑ I+a, .__-_ <br /> E] Yes Q No" For tank systams t t ulltize the monitoring system es the primary tank Overfill blaming d®vie 1,e., no mechanical t per prevention valve is <br /> I0 NIA Installed),m the ov II warning alarm viaiblc and audible at the tank 11W point(*)and opefabng Iopeny? If so,at what percent of tank capacity f <br /> does the alarm tagg r? U% <br /> Yes 0 No Was any monitortn equipment replarecI7 If yes identify specific sensors•probes,or other eq 'r'ment replaced snd list the manufacturer name <br /> and model tw ail fal lacement parts in Section E.below, <br /> ❑Yes• ® No Was licuid found ini de any secondary containment systems designed as dry systems? fCnecl Ili that apPty) <br /> ❑Product; ❑Wi er. I}yoa,describe opusoe in Section E,below. — <br /> ® Yes C] No- Was monitoring sy9 am set-up reviewed to ensure proper settings?Attach set up reports,if aop able <br /> ( Yes ❑ No' Is all M0Pgonng eq pment operational per manufacturer's specificatlona? I <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> II <br /> I-. comments. INSPECTOR HAS ALL PRINTOUTS , L <br /> i <br /> _ I <br /> I- <br /> _ <br /> ` 2/21/07 <br /> Monitoring System Gertlncation pegaZoT4 � <br /> f <br />
The URL can be used to link to this page
Your browser does not support the video tag.