My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 6:07:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2010 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 FEB 0 9 2015 <br /> Telephone:(209) 468-3420 Fax: (209)468-3433 Web:www.s' ov. alaw- <br /> - <br /> Underground Storage Tank Program Inspection R'epPt'�^r��•. „- <br /> Facility Name: Facility Address: Date: !' <br /> Sprint United Managemnt Co. 3807 Coronado Ave, Stockton November 07, 2014 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,.or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The diesel piping sump sensor was not at the lowest point and not located to detect a leak at the earliest opportunity. <br /> Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. The sensor <br /> was relocated to the lowest point of the sump during the inspection by the service technician. Ensure that all <br /> monitoring equipment is maintained to detect a leak at the earliest opportunity. This is a Class II violation. <br /> The Schrader valve on the return line in the diesel piping sump was not facing downward. The return line is gravity fed. <br /> This prevents any releases from the primary containment from immediately flowing into the secondary containment. <br /> Any potential release from the primary containment into the secondary containment in the diesel piping does not flow <br /> into a piping sump so that it can be detected at the earliest opportunity. All secondary containment systems shall be <br /> sloped so that all releases will flow to a collection sump located at the low point of the underground piping so that the <br /> monitoring equipment can detect a leak at the earliest opportunity. Immediately contact a properly licensed, trained, <br /> and certified contractor to ensure that any releases from the primary piping flows into the secondary containment piping <br /> sump so that a leak can be detected at the earliest opportunity. This is a Class II violation. <br /> Overall Inspection Comments: <br /> This report was amended on January 23, 2015. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by December 7, 2014. <br /> Consent to perform the inspection, take photos and collect samples was given by Ken Carr the Manager . This <br /> facility's designated operator is Darren M. Rieck (ICC expiration date: 5/1/15 ) . The service technician was Peter <br /> J. Jauregui III (ICC expiration date: 6/13/15 ), who had the following manufacturer's certifications: VR,7/7/15 . <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator: Written Agreement (if <br /> applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br /> Compliance. <br /> ALLEHDSTAFF I IME ASSOCLAIEDL BY AIES WILL BE SILLEDAT THE CURRENr HOURLYRATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received By(signature): Title: Date: <br /> Received By(printed name): Inspector: Inspector Phone: <br /> ARIS VELOSO, Senior REHS (209)468-3453 <br /> Page 5 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.