COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORRAL HOLLOW
>
18600
>
2300 - Underground Storage Tank Program
>
PR0231543
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:26 AM
Creation date
11/2/2018 6:18:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231543
PE
2381
FACILITY_ID
FA0009373
FACILITY_NAME
CARNEGIE SVRA
STREET_NUMBER
18600
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
25115002
CURRENT_STATUS
02
SITE_LOCATION
18600 CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORRAL HOLLOW\18600\PR0231543\COMPLIANCE INFO.PDF
QuestysFileName
COMPLIANCE INFO
QuestysRecordDate
11/5/2012 8:00:00 AM
QuestysRecordID
121240
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NDE ' S VPLT COMPUTERIZED TANK TESTING SYSTEM Patent Pending <br /> PRECISION UNDERGROUND TANK TESTING RESULTS AND CERTIFICATION <br /> PAGE 1 , SHORT REPORT FORM - Copyright 1985 <br /> NDE TECHNOLOGY, INC . PROPRIETARY <br /> TEST DATE: 11/23/1988 <br /> 1 . Owner of storage tanks STATE OF CALIFORNIA <br /> Department of Parks and Recreation' <br /> Company Representative Cody Begley <br /> Title Project Manager <br /> 2 . Mailing address of owner Department of General Services <br /> Office of the State Architect <br /> P. 0. Box 1079 <br /> Sacramento, CA 95812 <br /> 3 . Phone of owner (916) 322-8249 <br /> 4. STATION NUMBER Carnegie S . V. R. A. <br /> Location and address of 18600 Corral Hollow Road <br /> the tanks Tracy, CA 95376 <br /> Phone number (415) 447-9027 <br /> Regulatory Agency County of San Joaquin <br /> 5 . TANK DESIGNATION OR ID # K-CAR-01 <br /> 6. Date each tank was tested 11/23/1988 <br /> 7 . The name of the test method VPLT COMPUTERIZED TANK TESTING SYSTEM <br /> 8. Business name of tank <br /> testing company WESTERN AMERICA TANK TESTING, INC . <br /> 9. Mailing address of tank 3131 FAIRHAVEN DRIVE <br /> testing company BAKERSFIELD , CA 93308 <br /> 10. Person conducting test Brad Waggener (TECHNICIAN) <br /> and completing report <br /> 11 . Station Operator or Norm Foster <br /> manager <br /> 12 . Phone number (415) 447-9027 <br /> 13 . Owner name and STATE OF CALIFORNIA <br /> title Department of Parks and Recreation <br /> 14 . Capacity of the tank 1 , 000 gallons <br /> 15 . Present or past contents Unleaded <br /> 16. Tank construction material Steel <br /> 17. Testing fluid Unleaded <br /> 18. (a) THE UNDERGROUND STORAGE TANK SYSTEM CERTIFIED TIGHT AT PRODUCT <br /> HEIGHT EQUAL TO THE GRADE LEVEL. Yes. <br /> (b) Allowable leak resolution of instrumentation or allowable change <br /> per California Administrative Code Title 23 Waters , Chapter 3 <br /> Water Resources Control Board Subchapter 16 Underground Storage <br /> Regulations, Part 2643 (b) , Page 4 . 14; 0. 05 gallons per hour. <br /> *:k# (c) MEASURED HOURLY CHANGE : LOSS (+) OR GAIN (-) GALLONS OR <br /> NUMERICAL LEAK RATE IS : -0. 019 Gal/Hr. <br /> ------------------------------------------ ----------------------- <br /> This measurement is within the legal limits as defined in (b) . <br /> NDE TECHNOLOGY, INC . PROPRIETARY <br /> WATT INC . 3131 FAIRHAVEN DRIVE , BAKERSFIELD , CA 93308 (805) 322-9827 <br />
The URL can be used to link to this page
Your browser does not support the video tag.