My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2725
>
2300 - Underground Storage Tank Program
>
PR0231073
>
COMPLIANCE INFO 2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 1:34:02 PM
Creation date
11/2/2018 6:36:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231073
PE
2361
FACILITY_ID
FA0002064
FACILITY_NAME
7-ELEVEN INC. STORE #14117
STREET_NUMBER
2725
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
02
SITE_LOCATION
2725 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COUNTRY CLUB\2725\PR0231073\COMPLIANCE INFO 2008-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
402
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY 0 <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sigov,org/ehd/unitiii.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility address: Inspection ate: <br /> v �(;� 3 �p <br /> VI0LATI N(S) HSC=California Health&Safe Code;CCR=California Code of Regulations V R <br /> # Code Section V=Violation; RV=Repeat Violation V <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days;(e)test <br /> 2638 notification not provided to the EHD at least 48 hours prior to conducting an installation,repair,replacement, <br /> 24 CCR <br /> calibration,or certification;(f)performed,and failed to affix a tag/sticker on each monitoring equipment <br /> component that was certified,re aired,or replaced <br /> 25 CCR 2638 Annual line leak detector test:(a)not performed;(d)test report not submitted within 30 days (M1) <br /> 26 HSC 25284.2 Annual spill containment testing not performed <br /> 27 CCR 2636 f 4 Annual line tightness test not performed if positive shutdown or fail safe not present <br /> 28 CCR 2661 Repair for tank or piping not tested for tightness within 30 days of completion of the repair (M2) <br /> 29 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (M1) <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and retested. <br /> 32 CCR 2661 Permit to repair UST system not obtained <br /> 33 HSC 25286(a) Permit to alter monitoring system not obtained <br /> 34 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 35 HSC 25VaUST <br /> ermit to close UST system not obtained <br /> 36 HSC 25ampering with or disabling leak detection devices or alarms <br /> 37 HSC 25egally abandoned UST system <br /> 38 HSC 25nburied fuel piping at marinas not visually inspected at least monthly or log not kept <br /> 39 CCR 26system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 CCR 2636(f)(6) Emergency generator monitoring system not checked daily or log not kept (M1) <br /> 41 HSC 25281.5(b)(3) fuel piping not visuaily inspected at least monthly or log not kept (Ail1) <br /> Unburied <br /> VPHSystems HSC 25290.2 installed between 07/01/03 and 06/30/04 HSC 25290.1 (installed on or after 07101/04 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored; (b) <br /> 42 CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 2631(b)and(d)for a <br /> UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSC 25290.2(c)(1) <br /> 44 HSC 25290.1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 25290.2(c)(2) <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the entry of liquid <br /> HSC 25290.2(d) or vapor from the primary containment into the secondary containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space of the UST <br /> system not maintained <br /> 48 HSC 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection; (2)inert gas <br /> HSC 25290.2(i) pressure test approved by SWRCB;(3)test method deemed equivalent to(1)or(2)by the SWRCB <br /> Other violations <br /> 99 Other: <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br /> EHD 72ECTOR: PHONE: UIC <br /> W/ Septic system: <br /> F7 V r V Serves>20 people/day <br /> RECEIVED BY: TITLE: Receives other than sanitary waste <br /> Other disposal methods_ <br /> Dry wells/French Drains <br /> EHD 23-02-002 REV 12/09 Page 2 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.