MONITORING ALTERNATIVE FOR SINGLE WALL PRODUCT TANKS <br /> ELECTRONIC MONTHLY TANK MONITORING <br /> EQUIPMENT USED AT THIS FACILITY: Ronan System X76 ETM The equipment detects a leak rate of 0.2 gallons per hour <br /> during the four hour test. <br /> FACILITY ADDRESS: 1313E Charter Way. Stockton CA 95205 <br /> DAILY VISUAL OBSERVATION: On a daily basis the dealer or his designate will perform the inventory readout which will <br /> indicate that the sensor and the monitor control panel are working. <br /> MONTHLY TEST: Each tank will be tested monthly following the procedure listed on the attached. <br /> ANNUAL CERTIFICATION: The dealer will certify annually to the local agency listed below that he has performed all monthly <br /> tests and no leaks were indicated. <br /> Local Agency Name: County of San Joaquin O.E.S. <br /> Local Agency Address: 222 East Weber Ave.. Stockton <br /> Local Agency Phone: 209-468-3962 <br /> FAILED LEAK TEST: In the event of a failed leak test, the dealer will perform the steps outlined on the attached sheet <br /> entitled: "Monthly Test Procedures" Station personnel will also: <br /> 1. Notify the Responsible Personnel: <br /> Primary Contact: Name: Manoi Mahagam Title: Manager <br /> Address: 1619 Bridle Badhglc. #165. Stockton 95602 <br /> Bus #/Home #: 209-466-1901 / 209-474-2557 <br /> Secondary Contact: Name: Krishan Goval Title: Manager <br /> Address: 4000 Canyon Crest. San Ramon. Ca <br /> Bus #/Home #: 510-293-9150 / 510-293-9150 <br /> 2. Notify the Service Station Services at 1-800-887-8009 <br /> 3. Retest your tanks. <br /> YOU MUST RECEIVE A PASS TEST RESULT EVERY MONTH FOR EVERY PRODUCT AND KEEP TEST RESULTS IN YOUR <br /> GREEN BOOK. IF YOU DO NOT RECEIVE A PASS,YOU MUST NOTIFY THE SHELL H,S&E REPRESENTATIVE AT 510-675- <br /> 6143. <br /> MONTHLY TESTING PROCEDURES <br /> 1. Monthly, the system is programmed to perform a leak detection test. Each product tank will be tested separately. <br /> 2. Each tank will not have received a fuel drop not less than 4 hours before the test begins. (i.e. if the test starts at <br /> 12:01 A.M., then you must not receive a fuel delivery after 8:00 P.M. for the product being tested that evening.) <br /> 3. During testing, there will be no inputs or withdrawals from the tank. Pumping product during a test will invalidate <br /> the test. (Tests run from 12:01 A.M. to 5:00 A.M.) Tanks are initially programmed to test as follows: <br /> Regular - Morning of the 2nd <br /> Plus - Morning of the 3rd <br /> Premium - Morning of the 4th <br /> Diesel - Morning of the 5th <br /> 4 <br />