My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO 2011 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 11:14:22 AM
Creation date
11/2/2018 7:18:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2016
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95336
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\COLONY\1442\PR0518458\COMPLIANCE INFO 2011 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
547
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 3 of 4 <br />San Joaquin County^ <br />Environmental Health Department AME '-° j <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Narne: <br />CHEVRON STATION #210997* <br />Facility Address: <br />1442 Colon Dr, RIPON <br />Date: <br />Januar 21, 2016 <br />UST System Observations <br />321 <br />CCR 2636(c)(1) <br />All releases in secondary piping do not flow to a collection sump <br />o V e R <br />❑ COS <br />322 <br />CCR 2636(f)(2) <br />Line leak detector not installed <br />e V c R <br />❑ COS <br />323 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi <br />❑ V ❑ R <br />❑ COS <br />324 <br />CCR 2635(b) <br />No spill bucket installed or failed to provide a means to keep it empty <br />n V ❑ R <br />❑ COS <br />325 <br />CCR 2635(b) <br />Spill container failed to contain a minimum capacity of five gallons <br />e V e R <br />c COS <br />326 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements <br />❑ V n R <br />n COS <br />327 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />❑ V u R <br />o COS <br />328 <br />MSC 25283.5 <br />Unburied below grade UST failed to meet exemption status <br />e V o R <br />❑ COS <br />329 <br />CCR 2717.1(g) <br />Tampered with red tag <br />❑ V ❑ R <br />❑ COS <br />330 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R <br />❑ COS <br />331 <br />NSC 25299(f)(2) <br />Tampered with or disabled leak detection devices or alarms <br />e V c R <br />❑ COS <br />332 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />e V e R <br />❑ COS <br />333 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />Failed to comply with permanent closure requirements <br />e V o R <br />❑ COS <br />334 <br />HSC 25298(c) <br />V R <br />COS <br />Ntl Non-Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve c V o R <br />n COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre-Jan 1984) not performed c V n R <br />n COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre-January 1984) „ V e R <br />e COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre-January 1984) i,V ❑ R <br />c COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />Unlisted Operations/Maintenance violation <br />Unlisted Design/Construction violation <br />❑ V � R <br />e COS <br />2030 <br />See below <br />n V ❑ R <br />❑ COS <br />2060 <br />See below <br />❑ V n R <br />F COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS il, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />Overall Inspection Comments: <br />THE REPORT ISSUED ON 1-21-2016 WAS AMENDED BY THE EHD. THE AMENDED REPORT REPLACES <br />THE INITIAL REPORT. VIOLATION N. 201 WAS REMOVED FROM THE ORIGINAL REPORT. <br />A checklist of findings was issued on the day of inspection after the testing was completed, the inspector had <br />returned to the site to complete the routine UST inspection. A full report was issued on 1-21-2016 at the time of <br />inspection. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.