My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Vesda <br /> The Vesda system is to be tested by introducing a small quantity of smoke test spray <br /> designed for the use in testing smoke detectors. <br /> It will not be acceptable to light any type of fire that will produce smoke in a Sprint <br /> facility.NO EVENA SMALL AMOUNT FOR TESTING!I <br /> It is also required that when this testing is performed that the building halon system be <br /> disabled to prevent any accidental discharge of halon. <br /> It will also be necessary to determine if distinct hardwire Vesda alarms have been <br /> installed. <br /> If not then this will need to be done as soon as possible. <br /> The test will activate the 3 levels of alarm, Alert, Action and Fire and be verified by the <br /> BMC <br /> UST & AST <br /> The fuel probe is to be removed, cleaned and inspected. <br /> While on the ground the floats are to be moved to various locations on the probe and <br /> verified with BMC by measuring distance of float from the bottom of the probe. <br /> The fuel and water levels in the tank are to be taken by measuring with the tank dipstick <br /> and when probe is reinstalled the readings verified by BMC. <br /> The water level will need to be tested by utilizing water compound on the dipstick. <br /> This will indicate the water level in the tank. <br /> Fuel Leak <br /> The fill sump fuel leak sensor can be tested by manually raising and lowering the float <br /> Water Leak. <br /> The water leak sensor detects conductivity and should be tested by submerging in water. <br />