My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SNP-104-601 <br /> SNP- <br /> --&—Sj.�� <br /> p Network Practices (LDD,� iin/o1 <br /> Fuel Storage Tank Monitoring/Management Procedures <br /> Table of Contents <br /> 1. GENERAL...........................................................................................................................................................3 <br /> 1.1 PURPOSE........................................................................................................................................................3 <br /> 1.2 SCOPE.............................................................................................................................................................3 <br /> 13 RESPONSIBILITIES...........................................................................................................................................3 <br /> 1.4 REASON FOR REISSUE.....................................................................................................................................3 <br /> 2. CORROSION PROTECTION REQUIREMENTS.........................................................................................4 <br /> 3. ROUTINE TANK MAINTENANCE PROGRAM...........................................................................................S <br /> 3.1 ANNUAL TANK TIGHTNESS TESTS..................................................................................................................5 <br /> 3.1.1 Acceptable Tests....................................................................................................................................5 <br /> 4. TANK REPAIRS.................................................................................................................................................6 <br /> 4.1 COMPLIANCE WITH CURRENT EPA REGULATIONS.........................................................................................6 <br /> S. MONITORING AND LEAK DETECTION.....................................................................................................7 <br /> 5.1 PIPING MONrroRING.......................................................................................................................................7 <br /> 5.1.1 Underground:................................................... .......__.............................................. .............. 7 <br /> 5.1.2 Above Ground:......................................................................................................................................7 <br /> 5.2 IN TANK MONITORING....................................................................................................................................7 <br /> 5.2.1. Configuration and Programming..........................................................................................................8 <br /> 5.2.2 Operation...............................................................................................................................................8 <br /> 5.3 MONITORJNG..................................................................................................................................................8 <br /> 5.3.1 Local Control.........................................................................................................................................8 <br /> 5.3.2 Remote Control......................................................................................................................................8 <br /> 5.4 LEAK DETECTION...........................................................................................................................................8 <br /> 5.5 MAINTENANCE...............................................................................................................................................8 <br /> 6. PRODUCT INVENTORY CONTROL.............................................................................................................9 <br /> 6.1 ORDERING AND STORING DIESEL FUEL#2................................................................................................_....9 <br /> 6.2 TESTING DIESEL FUEL#2 QUALITY................................................................................................................9 <br /> 6.3 INCREASING THE LIFE OF STORED DIESEL FUEL#2........................................................................................9 <br /> 6.3.1Additives................................................................................................................................................9 <br /> 6.3.2 Circulation.............................................................................................................................................9 <br /> 6.4 DIESEL FUEL CONTAMINANTS......................................................................................................................10 <br /> 6.4.1 Water...................................................................................................................................................10 <br /> 6.4.2 Other Contaminants.........................................................................................................._ ..............1© <br /> 7. SPILL AND OVERFILL PREVENTION.......................................................................................................11 <br /> 7.1 SPILL PREVENTION.......................................................................................................................................11 <br /> 7.2 OVERFILL PREVENTION................................................................................................................................11 <br /> 7.3 OVERFILL CATCHMENTBASIN......................................................................................................................11 <br /> 8. REPORTING AND RECORD-KEEPING......................................................................................................12 <br /> 8.1 REPORTING...................................................................................................................................................12 <br /> 8.2 RECORD-KEEPING........................................................................................................................................12 <br /> 8.2.1 Leak Detection Peiformance and Upkeep...........................................................................................12 <br /> 1 <br /> Copyright 01999-2001 Sprint Corporation <br /> The information in this document is proprietary. Unauthorized disclosure of this information <br /> outside Sprint Corporation is prohibited. <br />
The URL can be used to link to this page
Your browser does not support the video tag.