Laserfiche WebLink
9 NPT threaded Isolating flex connectors at the shear valve <br /> CgfilleCtlOnS(COr3t'd) <br /> When flex connectors are directly buried at the dispenser,regulations frequently require <br /> that they be cathodically protected and provisions be made to avoid stray current " <br /> _r s,.�_ _ electrolysis and corrosion.In such cases the flex connector must be electrically isolated <br /> , <br /> r from the shear valve and from other metallic components in the system.Experience has <br /> Never use a pipe wrench directly shown that nylon isolation adapters do not perform well inasmuch as the poor <br /> on the pipe:wrench up only on <br /> adapters. mechanical strength of the material results in creep or thread deformation with <br /> � <br /> subsequent leakage. <br /> L---------- <br /> Ameron manufactures a 1'/a NPT female x 1'/z NPT male fiberglass-reinforced isolation <br /> adapter which maybe mounted between the flex connector and the shear valve. Follow <br /> the same general installation procedures as with other NPT threaded fittings.After <br /> applying the sealing compound,hand tighten the adapter.Final make-tap requires 11/2 <br /> to 2 additional turns. <br /> Shear valve <br /> pt r 1'/s NPTfemale <br /> �—21/a--0-- <br /> 11/2 NPT Dualoy isolation <br /> male adapter <br /> 2Y: <br /> Fig,9-1.TneAmeron fiberglass- <br /> reinforced isolation adapterls mounted SS flex connector <br /> between the flex connectorand the 1 ��1 Ya NPT male <br /> shear valve. both ends <br /> 11/2 NPT {by others) <br /> female <br /> I <br /> 10 Repair procedures Duafoy 3000/LCX is very resistant to impact damage.It can be damaged,however, <br /> by paving stakes,large concrete pieces or other hazards.in the event of damage,the <br /> pipe can be repaired using these procedures. <br /> Usually the damaged area is obvious.If the exact location of the damage cannot be <br /> determined, it may be necessary to replace that full leng.h of ripe.Standard leak <br /> detection methods(soapy water)can be applied progressively along the length of pipe <br /> to locate the damaged or defective section.If the primary pipe is leaking at an unknown <br /> location,the cut ends of the jacket at each end of each piece of pipe car be soaped to <br /> isolate the leak.If the containment pipe is leaking,the surface can be soaped. <br /> Minor damage(isolated to less than one inch of pipe length) <br /> • Cut out the damaged pipe. <br /> • Remove the jacket and taper each of the ends of the remaining pipe <br /> • Assemble coaxial coupling or primary coupling(molded coupling sleeve <br /> placed on pipe)following standard installation practices. <br /> • Assemble primary coupling following standard installation practices. <br /> Minor damage[containment only](isolated to less than one inch of pipe length) <br /> • Sand area around damaged area- approximately one inch in all directions. <br /> • Recover cutjacket section from field jacket removal tool,remove tape and <br /> sand from inner surface.Sand inner surface. <br /> • Apply thin coating of adhesive to sanded surfaces. <br /> • Wrap jacket section over pipe and secure in place until adhesive cures. <br /> Major damage(greater than one inch of pipe length) <br /> • Remove at least 15 inches of pipe length or the full length of pipe if damaged <br /> area is greater. <br /> • Remove the jacket and taper each of the ends of the remaining pipe <br /> • Dry fit two couplings and intermediate pipe nipple into the gap. <br /> • Proceed as above for each end of repair area.Finished repair is as shown on <br /> the next page. <br />