<br /> SHEET NO.DESCRIPTION SHEET NO.DESCRIPTION
<br /> 1 Title sheet
<br /> 2CX9200 & infinet layout
<br /> 2A Infinet layout (New Addition) 53 TCP47, LCX800:SensorsB3, LCX800:SensorsB4
<br /> 3 Chiller communications details 54 Chilled Water System Layout (New Addition)
<br /> 4 Chilled water system layout, chillers, pumps & cooling tower Q PHASE 2 55 Chiller Control Panel Detail
<br /> 5 Chilled water system wiring details, ex fans 1 & 2 56 Chillers, OA Dampers, SF-1 , Exhaust Fans and CRU'S Sequence Of Operation
<br /> 6 TCP1 , LCX810:Chillerl �Q PHASE 2 57 TCP48, SCX920:Chiller3
<br /> 7 TCP2, LCX810:Chiller2 58 TCP49, SCX920:Chiller4
<br /> 8 TCP3, SCX920:Tower1 59 TCP50, LCX810:Pumps 7---9
<br /> 9 TCP4, SCX920:Tower2 60 Computer Room Unit CRU-1 , Exhaust Fan EF-4 and OAL-5
<br /> 10 AHU 1 & humidifier HMI 61 TCP51 , SCX920:CRU--1
<br /> 11 TCPS, SCX920:AHU1 & control air pressure 62 Computer Room Units CRU-2 and CRU-3, Exhaust Fan EF-3 and OAL-4 1
<br /> 1 1 A TCPSA, DC POWER MONITORING 63 TCP52, SCX920:CRU-2 I
<br /> 12 AHU2 64 TCP53, SCX920:CRU-3
<br /> 13 TCP6, SCX920:AHU2 65 Computer Room Unit CRU--4 and Supply Fan SF-1
<br /> 14 AHU3 & humidifier HM2 & EDH366 TCP54, SCX920:CRU-4
<br /> 15 TCP7, SCX920:AHU3 67 Computer Room Unit CRU-5 and OAL-2 & 3
<br /> 16 AHU4 & WEATHER STATION (outside air & wind) 68 TCP55, SCX920:CRU-5
<br /> 17 TCPB, SCX920:AHU4 69Computer Room Unit CRU-6 and Exhaust Fan EF-2
<br /> 18 Halon alarm details, levels A & B 70 TCP56, SCX920:CRU-6
<br /> C 19 TCP9, LCX810:HalonA, LCX810:SensorsAl , TCX851 :SensorsA2 & EDH1 71 Computer Room Unit CRU-7
<br /> 20 TCP10, LCX810:SensorsA3, LCX800:UPS, elevator hoistway & hydrogen alarm 72 TCP57, SCX920:CRU-7
<br /> 21 TCP11 , LCX8IO:Holonl�, Lcx810:SensorsBl & EDI-12 73 Computer Room Unit CRU-8 and Exhaust Fan EF-1
<br /> 22 TCP12, LCX800:Sensors B2 & space static transmitters 74 TCP58, SCX920:CRU-8
<br /> 23 TCP13, LCX810:DoorsA 75 Computer Room Unit CRU-9 and OAL-7 & 8
<br /> 24 TCP14, LCX810:DoorsB 76 TCP59, SCX920:CRU-9 I
<br /> 25 Fire sprinkler flow, Storm & sewer pumps 77 Computer Room Unit CRU-10 and Exhaust Fan EF-5
<br /> 26 TCP15, LCX810:WoterWell & water well tank details 7$ TCP60, SCX920:CRU-10
<br /> 27 TCP16, LCX810:Alarms. AAA 7.9 TCP61 , LCX810:HalonC (New Addition)
<br /> 28 TCP17-23, Heat pumps /A\ 80 TCP62A, Main Electrical Service (New Addition)
<br /> 29 TCP24-27, Evap coolers A 81 TCP62, LCX800:Moin2
<br /> 30 TCP28, LCX810:ReliefFans & relief fan details 82 TCP63A, 1250KW Generator GEN4 (New Addition)
<br /> 31 TCP29, LCX800:Main Power, LCX810:TRSW A 83 TCP63, LCX810:GEN4
<br /> 32 TCP30, Main service IAA 84 1. Monitoring (New Tank #2)
<br /> 33 TCP31 , Transfer switches 1 -3 F QA 85L TANK #2 MONITORING
<br /> 0 34 TCP32, LCX810:Gen1 LA, 86 TGP65A, 300A Ups Monitoring (New Addition)
<br /> 35 TCP331 Generator # 1 AA 87 TCP65B, DC Power Monitoring (New Addition)
<br /> 0 36 TCP34, LCX810:Gen2 rc A 88 THIS SHEET, fl�LffED.UPS2 (New Addition) TITLE SHEET
<br /> 37 TCP35, Generator # 2 c 88A TCP65C, LCX810:UPS2 (New Addition) (Continued on sheet 1A)
<br /> A 38 TCP36, LCX810:Gen3 B 89 TCP66 : ACX-780 (ACCESS) Q WORK UNDER 19$BA0049AND, NEW ADDITION l
<br /> 39 TCP37, Generator # 3 A 90 MULTI--PROX CONTROLLER
<br /> �40 TCP38, UPS System A 91 DOOR LOCK DETAILS A WORK UNDER 199BA0113AND, Y2K UPGRADE
<br /> rG D 440A TCP38A, LCX810:UPS1
<br /> �ju .��j�details 0 WORK UNDER 1996A0229AND, SMC PROJECTS 1999
<br /> �' 0 42 �St3,L A WORK UNDER 200BA0390AND, MECHANICAL MODS.
<br /> el tank panel I
<br /> 43 TCP40, LCX810:Alarms-2 THERMAL. COMPONENTS COMPAN
<br /> '44 Heat exchanger details P.O. Box 1207 MiSSiON, KANSAS 66222
<br /> 45 TCP41 , LCX810:HeotEx
<br /> 0
<br /> REV15ED REVISED REVISED
<br /> 46 Cooling Tower CT-2 & Secondary CHW Pumps Wiring Details F REPLACEMENT OF MTS FUEL PROBES A 11-3-ss PROJE ON SWITCH CENTER
<br /> CT
<br /> WITH VEEOER-ROOT 3-27-00 3-24-98
<br /> 47 TCP42, LCX810:ClgTwr20 PHASE RWv E0 QREVISED REVISED 3807 ORONAAVE.
<br /> € 8 STOCKTON, CALLIFORNIA
<br /> 48 TCP43, LCX810x2:Pump5/Pump6 PHASE 2 1-24-01 5-11-99 5-7•-96
<br /> 49 Rooftop unit RTU- 1 (Typical of 2, RT-1A/RT-1B)Q PHASE 2 TR- AS BUILT OREVISED Sprint .
<br /> SPRINT COMMUNICATIONS CO. LARSON & BINKLEY ASSOCIATES
<br /> 50 $_12_99 TCP44, SCX920:RT1A 11_26_01 6-1-96 KANSAS CITY, MO. LEAWOOD, KS.
<br /> 51 TCP45, SCX920:RT1 BA PHASE 2 C REVISED REVISED DATE I ENGINEER IC E EO BY JOB NO, I SHEET
<br /> 52 TCP46 LCX800:SensorsA4 LCX800:SensorsA5PHASE 2 9-8-99 1 6-26-96 8-22-95 BILL BANKS 95A177 t
<br />
|