Laserfiche WebLink
Oe product overfilling [Section 2635(b)(2) (D)]. <br /> Manufacturer: OPW Model: 61 SO-40OC—EV R <br /> 18. PIPING INFORMATION <br /> 1 2 <br /> DISTANCE from <br /> Dl,';PENqFR to TANK 0 0 <br /> 0 0 <br /> SYSTEM TYPE- PetroFirst PetroFirst <br /> Steel Steel <br /> MAIERIAI *". Schl80 Sch80 <br /> LEAK DETECTION <br /> SYSTEM VeederRooVeederRa t <br /> 100%COMPATIBILITY <br /> _WLTH METHANOL Yes Yes <br /> CORROSION <br /> Fiber lass Fiberglass <br /> System Type; suctionbressurd, and gravity <br /> Construction: single-walled, double-walled, lined-trench, etc. <br /> Material Type; steel with cathodic protection,stainless-steel,fiberglass reinforced plastic. <br /> 19. YL-s Piping (cross-sectional diagram, including connections to tank and dispensers). <br /> (A) Vent and tank riser primary containment system equipped with overfill prevention system that: <br /> Restricts delivery of flow to tank[Section 2635(b)(2)(B)or(C)], or <br /> Yes Provide positive shut off of flow to the tank at no more than 95% [Section 2635(b)(2)(C)],or <br /> (B) Yes Vapor recovery piping designed so it cannot contain liquid phase product, or <br /> (C) Suction piping(below grade piping operates at less than atmospheric pressure)[Section 2636(a)(3)] <br /> NLA Sloped so contents of the pipe wi';drain back into the storage tank if the suction is released. <br /> _R,LA A No valves or pumps ins tilled below grade. <br /> Inspection method provided to demonstrate compliance with section 2636(a)(3). <br /> (D) A Corrodible underground piping protected against corrosion(Section 2636(b)). <br /> (E) N/A Underground primary piping will meet all of the following requirements <br /> Yes Primary piping in contact with hazardous substance under normal operation conditions shall be: <br /> installed inside a secondary containment system in the form of: secondary pipe Vault or <br /> lined trench to be sloped to a collection sump at the low point of the piping. <br /> Yes Primary piping and secondary containment systems will be installed in accordance with industry <br /> code of practice and voluntary consensus standards.. <br /> N/A Lined trench used as secondary containment <br /> Material compatible with the substance stored. <br /> Covered and capable of supporting any expected vehicular traffic. <br /> (F) Underground piping with secondary containment will be equipped and monitored as follows:. <br /> Yes Secondary containment will be equipped with a continuous monitoring system connected to an <br /> audible and visual alarm system, <br /> 8 <br />