Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209) 468-3433 Web:www.sagov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A G SPANOS AVIATION DEPT' 4800 S AIRPORT WAY, STOCKTON February 24, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment. <br /> Releases from the flex piping in the L11 transition sump were not fully recorded. The site is keeping partial written <br /> records of the releases, which include the date, the quantity, and basic disposal information. One log example: <br /> "The week of Nov 18th removed 1 gallon of fuel from L-11 Trans Sump. Placed absorbent pad in waste barrel." <br /> Any release from the primary containment that does not escape the secondary containment and was cleaned up <br /> within eight hours of being detected shall be recorded with the following information: <br /> 1. Operator's name and phone number <br /> 2. List of types, quantities, and concentrations of hazardous substances released <br /> 3. Description of actions taken to control and clean the release <br /> 4. Method and location of disposal of the released substances <br /> 5. Description of actions taken to repair and prevent future releases <br /> 6. Description of method used to reactivate interstitial monitoring after repair or replacement of primary <br /> containment <br /> Immediately record this release with the complete information required, and maintain it on site with the facility's <br /> monitoring records. Submit a copy of the recordable release statement to the EHD. <br /> This is a minor violation. <br /> 313 HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product-tight. <br /> A work order from Elite IV indicates a product leak was identified on May 9, 2016 from the flex line inside the L11 <br /> transition sump. A permit for flex piping replacement was submitted on May 10, 2016 and was approved on May <br /> 26, 2016. The piping was replaced and the leak fixed on February 24, 2017 during the monitoring system <br /> certification, almost 10 months after initial discovery. All primary containment for the UST system must be tight. <br /> Take all steps necessary to ensure primary containment is operated and maintained product-tight at all times. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by March 29, 2017. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS):UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Documents reviewed: alarm history, alarm logs, CERS submittals, designated operator monthly reports, <br /> designated operator training records, test results, maintenance records/work-orders <br /> Documents provided: Return to Compliance Certification form, scheduled Certified Unified Program Agency <br /> (CUPA) class schedules. <br /> FA0003809 PR0231509 SCO01 02/24/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OR <br />